Inspection Status: Denied
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 06/14/2000 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999* |
| 09/01/1999 |
BUILDING - FINAL |
|
Correction Required |
ADDTL COMMS - 1. THE KITCHEN COUNTER PLUGS ARE SUPPOSED TO BE ON TWO CIRCUITS WHICH SERVE THOSE PLUGS ONLY. 2. THE DISHWASHER AND DISPOSER PLUG CANNOT BE ON THE KITCHEN CIRCUIT. CORRECT AND RECALL. 3. THE KITCHEN LIGHTING CANNOT BE ON THE COUNTER PLUG CIRCUIT. RECEPTACLES W/G F1 PROTECTION MUST BE ADDED TO ISLAND AND PENNINSULA COUNTERS. |
| 09/01/1999 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999* |