Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T98BU00587
Permit Details
Status:
Final
Type:
COMMERCIAL OTHER
Address:
3855 N SILVERBELL RD
Address NEW:
3855 N SILVERBELL RD
Apply Date:
03/09/1998
Applicant:
RICK ENGINEERING
Description:
GRADING:21000CY CUT & 21000CY FILL
Contractors:
- U S HOME OF ARIZONA *P *C
Completed Inspections
Permit Status: Final
Permit Number: T98BU00587
Permit Description: GRADING:21000CY CUT & 21000CY FILL
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/22/2002 | GRADING - FINAL | JBRUCKME | Approved | FINAL GRADING DENIED. LOCATION: CORTE ALBOR - BETWEEN LOTS 107 & 108 1) THE STORM DRAINAGE PIPE IS ONLY 36" OF THE REQUIRED 42" INDICATED ON THE GRADING PLAN. PROVIDE REVISED DRAWINGS AND CALCULATIONS TO SHOW THAT DRAINAGE REQUIREMENTS HAVE BEEN MET. 2) CATCH BASIN INLET HAS CONCRETE WASH OUT BUILD UP. REMOVE ALL SEDIMENT AND CONSTRUCTION DEBRIS FROM DRAINAGE AREAS. 3) EROSION AT THE BASE OF THE ROCK RIP RAP PROVIDED AT THE DISCHARGE END OF THE 36" STORM DRAIN. REPAIR EROSION DAMAGE. LOCATION: UPSTREAM OF CORTE ALBOR - BETWEEN LOTS 112 &113. 1) EROSION AT THE UPSTREAM SIDE OF THE ROCK RIP RAP AT THE INLET TO THE 30" SRP. PLEASE REPAIR THE EROSION DAMAGE. LOCATION: PLACITA DEL COMIENZO BETWEEN LOTS 112 &113. 1) REMOVE CONSTRUCTION SEDIMENT DEPOSITED DOWNSTREAM OF THE SIDEWALK SCUPPER |
| 10/22/2002 | LANDSCAPE INSPECTION | PGILBERT | Approved | |
| 03/02/2005 | PERMIT FINALED | DHERRON | Approved |