Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
MOBILE HOME: PRIVATE LOT
Address:
608 N CUESTA AV
Address NEW:
608 N CUESTA AV
Apply Date:
10/02/1997
Applicant:
TUPIKEN MARIA YOLANDA
Description:
MOBILE HOME:SETUP

Outstanding Inspections

Permit Status: Expired
Permit Number: T97MH00347
Permite Description: MOBILE HOME:SETUP
Total Outstanding Inspections - 8
Last Inspection Date Description Inspector Results Comments
MOBILE HOME ACCESSORIES N/A Not Inspected
MOBILE HOME FINAL N/A Not Inspected
PERMIT FINALED N/A Not Inspected
08/29/2000 MOBILE HOME SITE LOC./SET-UP N/A Denied NO INSTALLER ID, HUD-ARZ038593
1) MISSING MARRIAGE LINE SUPPORTS
08/29/2000 MOBILE HOME UNDERGROUND GAS N/A Denied 1) INSTALL FLEX CONNECTOR. 2) INSTALL SHUT-OFF VALVE
08/29/2000 MOBILE HOME UNDERGROUND GAS N/A Denied GAS DENIED INSTALL FLEX CONNECTED
INSTALL SHUT OFF VALVE
08/29/2000 MOBILE HOME ELECTRICAL N/A Denied 1) CONDUIT OVERFILLED. 2) 200 AMP SERVICE DISCONNECT SHOULD BE 100 AMD MAX. 3) ELECTRODE GROUNDING CONDUCTOR TO BE CLAMPED TO GROUNDING ELECTRODE. 4) HOME'S CROSS-OVER CONNECTIONS NOT INSTALLED. 5) MISSING GROUND BONDING JUMPER BETWEEN 1/2'S OF HOME. 6) SERVICE GROUND NOT PROPERLY IDENTIFIED IN SUB-PANEL. 7) NEED NAME AND LICENSE # OF LICENSED ELECTRICIAN DOING WORK.
08/29/2000 MOBILE HOME PLUMBING N/A Denied 1) INSTALL BACKFLOW DEVICE ON HOSE BIB.

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW