Permit: T97CM02775
Permit Details
Apply Date:
09/04/1997
Applicant:
SKYLINE HOMES
Description:
SFR:TD#07-01-96
Contractors:
- SKYLINE HOMES
Outstanding Inspections
Permit Status: Expired
Permit Number: T97CM02775
Permite Description: SFR:TD#07-01-96
Total Outstanding Inspections - 9
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| BUILDING - FINAL | N/A | Not Inspected | ||
| ELECTRIC - FINAL | N/A | Not Inspected | ||
| PLUMBING - YARD WTR LINE/TEST | N/A | Not Inspected | ||
| PLUMBING - GAS PRESSURE TEST | N/A | Not Inspected | ||
| MECHANICAL - FINAL | N/A | Not Inspected | ||
| PERMIT FINALED | N/A | Not Inspected | ||
| 01/26/1998 | PLUMBING - FINAL | N/A | Denied | NO SEWER |
| 10/15/1997 | STEM WALL/RETAINING WALL | N/A | Denied | DENIED |
| 11/13/1997 | EXT METAL CLIPS/EXT SHEATHING | N/A | Correction Required | ADDTL COMMS - 1. THE GARAGE DOOR BEAM WILL HAVE TO BE STRAPPED AT EACH END BOTH INSIDE & OUTSIDE WITH A STRAP 18 LONG. 2. DO NOT FLATTEN A2.5 ANGLE STRAPS. THEY ARE NOT TESTED, APPROVED, OR LISTED IN FLAT FORM. USE COIL STRAP, FLAT STRAP, OR FHA STRAPS. ADD FLAT STRAP AT EACH HEADER OR BEAM IN BEARING WALLS. 3. MARK EACH BUILDING WITH ITS ADDRESS WHICH? 4. A3.5 STRAPS ARE UNDER NAILED. |