Permit: T97CM02775

Parcel: 130022110


Addresses:

1813 S 30TH PL

Inspection Status: Correction Required

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
11/13/1997 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. THE GARAGE DOOR BEAM WILL HAVE TO BE STRAPPED AT EACH END BOTH INSIDE & OUTSIDE WITH A STRAP 18 LONG. 2. DO NOT FLATTEN A2.5 ANGLE STRAPS. THEY ARE NOT TESTED, APPROVED, OR LISTED IN FLAT FORM. USE COIL STRAP, FLAT STRAP, OR FHA STRAPS. ADD FLAT STRAP AT EACH HEADER OR BEAM IN BEARING WALLS. 3. MARK EACH BUILDING WITH ITS ADDRESS WHICH? 4. A3.5 STRAPS ARE UNDER NAILED.
11/13/1997 EXT METAL CLIPS/EXT SHEATHING Denied DENIED