Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T97CM01210
Permit Details
Apply Date:
05/09/1997
Applicant:
CHIRCO CONSTRUCTION CO INC ,
Description:
SFR:PRIV GAR:PORCH:FIREPLACES:A/C:TD#12-05-61
Contractors:
- CHIRCO CONSTRUCTION CO INC ,
Completed Inspections
Permit Status: Final
Permit Number: T97CM01210
Permit Description: SFR:PRIV GAR:PORCH:FIREPLACES:A/C:TD#12-05-61
Total Completed Inspections - 2
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/16/1997 | ROOF NAILING | RFREIDIN | Approved | ADDTL COMMS - DONT LOAD ROOF UNTIL HANGERS FIXED, NEED SPECS ON ALPINE GIRDER JOIST HANGER, 14 16D SIMPSON NAILS TO BE USED IN HUS26 HANGER NOT 10D GUN NAILS, X BRACE TRUSSES EACH END AT 25, NEED RAT RUNS AT GARAGE DROP CEILING, REMOVE BLOCK AT REAR BEARING WALL TO REVEAL BEARING OF TRUSSES |
08/14/1997 | PLUMBING - INTERMEDIATE | HLEYVA | Approved | PARTIAL APPROVAL |