Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Correction Required
Inspection History: ROOF NAILING
Permit Number - T97CM01210
Inspection Description - ROOF NAILING
Inspection Status - Correction Required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/16/1997 | ROOF NAILING | Correction Required | ADDTL COMMS - DONT LOAD ROOF UNTIL HANGERS FIXED, NEED SPECS ON ALPINE GIRDER JOIST HANGER, 14 16D SIMPSON NAILS TO BE USED IN HUS26 HANGER NOT 10D GUN NAILS, X BRACE TRUSSES EACH END AT 25, NEED RAT RUNS AT GARAGE DROP CEILING, REMOVE BLOCK AT REAR BEARING WALL TO REVEAL BEARING OF TRUSSES |