Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T97CM01210

Parcel: 133553050


Addresses:

9559 E SALVATORE PL


Inspection Status: Correction Required

Inspection History: ROOF NAILING

Permit Number - T97CM01210

Inspection Description - ROOF NAILING

Inspection Status - Correction Required

Date Description Inspector Results Comments
07/16/1997 ROOF NAILING Correction Required ADDTL COMMS - DONT LOAD ROOF UNTIL HANGERS FIXED, NEED SPECS ON ALPINE GIRDER JOIST HANGER, 14 16D SIMPSON NAILS TO BE USED IN HUS26 HANGER NOT 10D GUN NAILS, X BRACE TRUSSES EACH END AT 25, NEED RAT RUNS AT GARAGE DROP CEILING, REMOVE BLOCK AT REAR BEARING WALL TO REVEAL BEARING OF TRUSSES