Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T97CM01078
Permit Details
Apply Date:
04/30/1997
Applicant:
THE IEF GROUP INC
Description:
TI:PARKS DEPARTMENT MAINTENANCE BUILDING *WILDAN* WAREHOUSE AREA CONVERSION TO OFFICES(CHANGE OF OCCUPANCY) S (WAREHOUSE) TO B OFFICES METAL STUDS AND GYP. BD.
Contractors:
- RALLY CONSTRUCTION COMPANY INC ,
Completed Inspections
Permit Status: Final
Permit Number: T97CM01078
Permit Description: TI:PARKS DEPARTMENT MAINTENANCE BUILDING *WILDAN* WAREHOUSE AREA CONVERSION TO OFFICES(CHANGE OF OCCUPANCY) S (WAREHOUSE) TO B OFFICES METAL STUDS AND GYP. BD.
Total Completed Inspections - 5
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/08/1997 | EXT METAL CLIPS/EXT SHEATHING | DWILLETT | Approved | DENIED |
08/08/1997 | EXT METAL CLIPS/EXT SHEATHING | DWILLETT | Approved | ADDTL COMMS - 1. PLYWOOD ON EXT. TO BE GLUED & SCREWED TO STUDS, SEE 3/A2.1. 2. PLYWOOD NOT ATTACHED TO TOP PLATE. 3. BUTT JOINTS @ PLYWOOD NOT NAILED IN AREAS, NEED BLOCKING. CHECK ALL. 4. S.WEST CORNER OF BUILDING-PLYWOOD NOT NAILED. 5. CONSULT ARCH. 0OF RECORD REGARDING THE MANNER IN WHICH PLYWOOD HAS BEEN FASTENED TO STUDS. GET WRITTEN, STAMPED APPROVAL IF ACCEPTABLE. 6. HAVE ON SITE AT NEXT INSPECTION.7. ANY MASONRY OR CONCRETE FOOTINGS NEED INSPECTION. |
08/19/1997 | STUCCO MESH | DWITT | Approved | ADDTL COMMS - FOOTING @ NORTH END OF COFFICORE INFILL OK |
09/19/1997 | SHEET ROCK NAILING | DWITT | Approved | ADDTL COMMS - 1. RESCREW WHER SCREWS ARE LESS THAN 3/8 FROM EDGE. 2. RESCREW WHERE PAPER IS BROKEN. 3. FINISH SCREWING. |
12/31/1997 | BUILDING - FINAL | DWITT | Approved | NOT READY FOR INSPECTION |