Permit: T97CM00698
Permit Details
Apply Date:
04/04/1997
Applicant:
LIPINSKI DAVID ALAN & LINDA JEAN
Description:
CUSTOM HOME
Permit Reviews
Permit Number - T97CM00698
Permit Status: Closed
Permit Description: CUSTOM HOME
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
10/30/2001 | REVISION | 10/30/2001 | COMPLETED |
11/01/2001 | REVISION | 11/01/2001 | COMPLETED |
Outstanding Inspections
Permit Status: Closed
Permit Number: T97CM00698
Permite Description: CUSTOM HOME
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/10/2005 | BUILDING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* 1) CALLED 2:31 PM AND LEFT MESSAGE I WAS ON WAY ARRIVED AT 2:47 PM AND CALLED AGAIN. KNOCKED ON BOTH DOORS AND WALKED ACROSS STREET TO 2601 W. ARTHUR. COULD NOT LOCATE OWNER LEFT SITE AT 3:00 PM |
11/10/2005 | ELECTRIC - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* |
Completed Inspections
Permit Status: Closed
Permit Number: T97CM00698
Permit Description: CUSTOM HOME
Total Completed Inspections - 21
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/11/1997 | PLUMBING - YARD WTR LINE/TEST | MCAPISTR | Approved | OK TO COVER PVC TRENCH |
11/26/1997 | BUILDING PRE-SLAB | LRUDER | Approved | |
11/26/1997 | BUILDING PRE-SLAB | LRUDER | Approved | ADDTL COMMS - 1. WRAP PLUMBING PIPES. 2. SUB GRADE SHOWS YOU HAVE LESS THAN 1 OF CONCRETE IN MIDDLE OF FLOOR. |
11/06/1998 | EXT METAL CLIPS/EXT SHEATHING | DWILLETT | Approved | NOT READY FOR INSPECTION |
11/06/1998 | EXT METAL CLIPS/EXT SHEATHING | DWILLETT | Approved | ADDTL COMMS - PROGRESS OKAY FOR 180 DAYS EXTENTION |
04/13/1999 | ELECTRIC - CABLE DROP | RAIELLO | Approved | ADDTL COMMS - OKAY TO CLEAR CABLE DROP |
12/19/1999 | PLUMBING - ROUGH, SOIL | RFREIDIN | Approved | IVRS - Inspection 0000* |
12/19/1999 | PLUMBING - ROUGH, SOIL | RFREIDIN | Approved | ADDTL COMMS - PROGRESS ONLY OK. |
11/17/2000 | MECHANICAL - INTERMEDIATE | EDURAZO | Approved | |
11/17/2000 | PLUMBING - GAS PRESSURE TEST | EDURAZO | Approved | |
11/17/2000 | PLUMBING - INTERMEDIATE | EDURAZO | Approved | |
11/17/2000 | U VALUE FOR WINDOW | EDURAZO | Approved | |
11/17/2000 | FRAMING | EDURAZO | Approved | 1. DO NOT SHEETROCK OR COVER WITH ANY MATERIAL UNTIL ALL INTERMEDIATES HAVE BEEN APPROVED. 2. 30" MIN. CLEARANCE REQ'D AT ALL WATER CLOSET. 3. AS PER MR. LIPINSKI-HE IS TO HIRE A LIC. ELECTRICIAN AND PLUMBER TO COMPLETE THESE TRADES. 4. STAIRS RISE AND RUN SHALL BE WITHIN 3/8" TOLERANCE. CHECK ALL STAIRS. 5. REVISE DRAWING TO CONFORM WITH AS BUILTS. HAVE APPROVED DRAWING ON SITE FOR INPSECTION, MEHANICAL, ELECTRICAL AND PLUMBING. |
01/24/2001 | STUCCO MESH | DBRITO | Approved | IVRS - Inspection 0000* |
11/26/2001 | ELECTRIC - INTERMEDIATE | JORTA | Approved | IVRS - Inspection 0000*ROUGH ELECTRICAL APPROVED BASE BOARD HEATING TO BE INSTALLED PER INSTRUCTION AND INDUSTY STANDARD DO NOT COVER UNTIL AUTHORIZED TO DO SO ALL CODER TO BE APPROVED FOR FINAL. |
05/24/2002 | STEM WALL/RETAINING WALL | LHANLY | Approved | IVRS - Inspection 0000* |
05/24/2002 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection 0000*PER MAC CAPISTRANO |
10/04/2002 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection 0000* |
04/03/2003 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000*EVAP. COOLED BASE BOARD HEAT. |
09/29/2003 | PLUMBING - FINAL | JRIVA | Approved | IVRS - Inspection 0920*/ 1) NO ANSWER AT EITHER DOOR. NO ACCESS, PLEASE RESCHEDULE |
11/10/2005 | ELECTRIC - UNDERGROUND | LHANLY | Approved | IVRS - Inspection :* |