Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Sign - Permanent
Apply Date:
09/22/2022
Applicant:
Gloria Ice
Description:
wall signs for hotel

Permit Reviews

Permit Number - T22OT00690
Permit Status: Issued
Permit Description: wall signs for hotel
Start Date Submittal Complete Date Status  
02/06/2023 PERMANENT SIGN REVIEW v.4 03/01/2023 REQUIRES RESUBMIT Review Details
03/07/2023 PERMANENT SIGN REVIEW v.6 03/09/2023 APPROVED Review Details
11/04/2022 PERMANENT SIGN REVIEW v.1 12/06/2022 REQUIRES RESUBMIT Review Details
01/04/2023 PERMANENT SIGN REVIEW v.3 01/06/2023 REQUIRES RESUBMIT Review Details
12/15/2022 PERMANENT SIGN REVIEW v.2 12/20/2022 REQUIRES RESUBMIT Review Details
03/06/2023 PERMANENT SIGN REVIEW v.5 03/06/2023 REQUIRES RESUBMIT Review Details

Outstanding Inspections

Permit Status: Issued
Permit Number: T22OT00690
Permite Description: wall signs for hotel
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
09/30/2022 COT - ENGR - Signage Final N/A Complete (Recurring) {Activity date: 09/30/2022; Status: Continued; Inspector: Hthrall; Comment: Entered by HTHRALL1 - RE: sign review
For: Springhill Suites
AT: 1705 E Tucson Marketplace Bl
Sign permit: T22OT00690
Reviewer: H. Thrall
Date: 09/28/22

Codes: Unified Development Code (UDC) 7A. Sign Standards, National Electrical Code (NEC), Tucson- Pima County Outdoor Lighting Code (OLC), International Building Code (2018) IBC

1. UDC:
A. Obtain developer permission for the signage proposed - provide written permission.
B. On Sheet 2 site plan sheet - Dimension the length of each street front property line for just the hotel use along both South Kino and E Tucson Marketplace Blvd. (i.e. north boundary to corner of intersection, then from that point west to the driveway entry. The allowed sign area is 3 square feet per each linear foot of the dimensioned lot line area.
C. All wall signs are boxed in a manner that uses a tremendous amount of negative space. Box the signage such that each line is separate and update the permit application - and on the plans dimension each sign and provide revised sign area next to each sign (i.e. Springhill Suites is sign A, then By Marriott is Sign B, for example for south elevation sheet ).

2. NEC / OLC: all signs; each page of plan set- add notes as follows:
A. Add Note with location of timer within the building for inspection purposes.
B. Add note with the location of breaker panel within the building
C. Add note all signs and power supply components are UL listed
D. Add note that all signs shall have UL sticker, manufacturer sticker and installer sticker located on the exterior of the sign for inspections
E. Add note all dedicated sign circuits shall be labeled
F. Add note "24 hour operational business, timer provided but is not subject to midnight curfew"
G. Add notes that a lock out will be provided for each sign

3. IBC:
A. List type of metal these letter are made of.
B. Add note with the size of the lag bolt (i.e. length / diameter) and typical number per letter - this bolt should be significant due to the height off the ground for these letters.

4. NOTE ON PLANS THAT ACCESS WILL BE PROVIDED BY THE CONTRACTOR TO EACH SIGN FOR INSPECTIONS

Please send revised plans to Heather.Thrall@tucsonaz.gov
}

Documents

File Name Document Type  
SPRINGHILLSUITESTUCSONMARKETPLACEAPPREV (1)_V5.PDF DOCUMENTS VIEW
SPRINGHILLTUCSONSITEWALL_V5.PDF DOCUMENTS VIEW
SPRINGHILLTUCSONWALLSIGNS_V6.PDF DOCUMENTS VIEW