Permit: T22CM06741
Permit Details
Status:
Issued
Type:
Residential Building - One or Two Family
Address:
2301 N WALNUT AV
Address NEW:
2301 N WALNUT AV
Apply Date:
09/01/2022
Applicant:
Description:
R-Master Suite and Laundry Addition
Permit Reviews
Permit Number - T22CM06741
Permit Status: Issued
Permit Description: R-Master Suite and Laundry Addition
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/01/2022 | RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO | 09/20/2022 | COMPLETED |
| 09/28/2022 | RESUBMITTAL | 10/13/2022 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T22CM06741
Permit Status: Issued
Permit Description: R-Master Suite and Laundry Addition
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/12/2022 | SHOP DRAWINGS REQUIRED FOR TRUSS. |
Conditions
Permit Number - T22CM06741
Permit Status: Issued
Permit Description: R-Master Suite and Laundry Addition
| Date | Description | Comments |
|---|---|---|
| 10/12/2022 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. | |
| 10/13/2022 | General Contractor Letter (GCL) or Owner/Builder Waiver required prior to permit issuance |
Outstanding Inspections
Permit Status: Issued
Permit Number: T22CM06741
Permite Description: R-Master Suite and Laundry Addition
Total Outstanding Inspections - 12
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/26/2022 | COT - RSEL - Grounding/Bonding | N/A | Not Ready | |
| 10/26/2022 | COT - RSBU - Roof Nailing | N/A | Not Ready | |
| 10/26/2022 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Not Ready | |
| 10/27/2022 | COT - RSME - Mechanical Final | N/A | Not Ready | |
| 10/27/2022 | COT - LCBU - Framing | N/A | Not Ready | |
| 10/26/2022 | COT - RSBU - Preslab | N/A | Not Ready | |
| 10/27/2022 | RSBU - Building Final | N/A | Not Ready | |
| 10/27/2022 | COT - RSEL - Outdoor Lighting | N/A | Not Ready | |
| 10/27/2022 | COT - RSPL - Plumbing Final | N/A | Not Ready | |
| 10/27/2022 | RSME - Mechanical Progress | N/A | Not Ready | |
| 10/26/2022 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Not Ready | |
| 02/23/2023 | COT - RSEL - Electrical Final | N/A | Not Ready | No approved plans on site. |
Completed Inspections
Permit Status: Issued
Permit Number: T22CM06741
Permit Description: R-Master Suite and Laundry Addition
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/24/2023 | COT - RSEL - Service Upgrade | Passed | INCR clearance code. unable to enter in other area of inspection. |