Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Residential Building - One or Two Family
Apply Date:
07/11/2022
Applicant:
Russ Salmon
Description:
SFR LENNLE4003 T22-M0047

Outstanding Activity Conditions

Permit Number - T22CM05223
Permit Status: Issued
Permit Description: SFR LENNLE4003 T22-M0047
Total Outstanding Activity Conditions - 6
Date Name
07/11/2022 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
07/11/2022 ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I)
07/11/2022 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
07/11/2022 NO FINAL UNTIL THE PUBLIC SEWER G-2020-90/P21WP00062 IS ACCEPTED AND RELEASED BY PCRWRD
07/14/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
07/14/2023 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.

Outstanding Inspections

Permit Status: Issued
Permit Number: T22CM05223
Permite Description: SFR LENNLE4003 T22-M0047
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
10/26/2022 COT - RSPL - Sewer N/A Not Ready
10/27/2022 COT - RSPL - Plumbing Final N/A Not Ready

Completed Inspections

Permit Status: Issued
Permit Number: T22CM05223
Permit Description: SFR LENNLE4003 T22-M0047
Total Completed Inspections - 24
Date Description Inspector Results Comments
08/18/2022 COT - RSPL - Yard Water Line Passed {Activity date: 08/18/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - approved}
08/18/2022 COT - RSPL - Rough Soil Passed {Activity date: 08/18/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - approved. Shading required.}
08/23/2022 COT - RSEL - Electrical Underground Passed {Activity date: 08/23/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
08/23/2022 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 08/23/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
08/25/2022 COT - RSEL - Grounding/Bonding Passed {Activity date: 08/25/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 08/23/2022; Status: Denied; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - DE isolate ufer from form, clean ufer trench}
08/25/2022 COT - RSBU - Preslab Passed {Activity date: 08/25/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 08/23/2022; Status: Denied; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - DE}
10/14/2022 COT - RSBU - Roof Nailing Passed {Activity date: 10/14/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 10/06/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - approved} ; {Activity date: 10/04/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
10/20/2022 COT - RSBU - Exterior Clips/Sheathing Passed {Activity date: 10/20/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - approved} ; {Activity date: 10/14/2022; Status: Denied; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Denied. Missing anchor bolts in garage, missing second stud at stairwell, shim floor trusses. Missing 12 foot shearwall.} ; {Activity date: 10/06/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - not ready. Missing clips above headers and trim studs. Loose shear walls top floor East and west side of building. Add more nails at bottom plates second floor.} ; {Activity date: 10/04/2022; Status: Denied; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - . DE
1. Framing at south window openings are not per plan
2. Hallways and openings to hallways cannot be framed less than 37 inches
3. Install anchor bolts within 12” of end of shear wall. Hold downs cannot substitute for anchor bolts
4. Install anchors for HTT hold downs
}
12/15/2022 COT - RSEL - Construction Power Passed
12/15/2022 BULD - Electrical Clearance Passed TEP ECO
03/13/2023 COT - RSPL - Gas Pressure Test Passed
03/13/2023 RSME - Mechanical Progress Passed
03/13/2023 COT - LCPL - Plumbing Intermediate Passed
03/14/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
03/14/2023 COT - LCBU - Framing Passed
03/22/2023 COT - HCBU - Interior Shear Bracing Passed Approved. Corrections were made. 3/22/2023
04/10/2023 COT - RSPL - Sewer Passed
07/11/2023 COT - BULD - SWG Clearance Passed 7/11/23: SWG Clearance for meter only.
09/18/2023 COT - RSPL - Plumbing Final Passed
09/18/2023 COT - RSEL - Electrical Final Passed
09/18/2023 COT - RSME - Mechanical Final Passed
09/18/2023 RSBU - Building Final Passed
09/18/2023 COT - RSEL - Outdoor Lighting Passed
09/18/2023 ENGR Engineering Final Passed

Documents

File Name Document Type  
APPLICATION.PDF DOCUMENTS VIEW
JOB CARD.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
SIC.PDF DOCUMENTS VIEW
SITE PLAN.PDF DOCUMENTS VIEW