Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/20/2022 | COT - RSBU - Exterior Clips/Sheathing | SCARRAZCO | Approved | Entered by NGARCIA3 - approved |
10/14/2022 | COT - RSBU - Exterior Clips/Sheathing | ESTEVENS | Denied | Entered by NGARCIA3 - Denied. Missing anchor bolts in garage, missing second stud at stairwell, shim floor trusses. Missing 12 foot shearwall. |
10/06/2022 | COT - RSBU - Exterior Clips/Sheathing | SCARRAZCO | Not ready for Inspection | Entered by NGARCIA3 - not ready. Missing clips above headers and trim studs. Loose shear walls top floor East and west side of building. Add more nails at bottom plates second floor. |
10/04/2022 | COT - RSBU - Exterior Clips/Sheathing | TLUNDBERG | Denied | Entered by NGARCIA3 - . DE 1. Framing at south window openings are not per plan 2. Hallways and openings to hallways cannot be framed less than 37 inches 3. Install anchor bolts within 12” of end of shear wall. Hold downs cannot substitute for anchor bolts 4. Install anchors for HTT hold downs |