Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T22CM04386
Permit Details
Apply Date:
06/13/2022
Applicant:
Description:
TI: offices/rooms
Permit Reviews
Permit Number - T22CM04386
Permit Status: Complete
Permit Description: TI: offices/rooms
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/13/2022 | COMMERCIAL - BLDG/FIRE/ZONING/ENG | 07/14/2022 | COMPLETED |
| 08/02/2022 | RESUBMITTAL | 08/05/2022 | COMPLETED |
| 05/10/2023 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 05/24/2023 | APPROVED |
| 03/20/2023 | COMMERCIAL REVIEW - FULL v.1 | 04/24/2023 | REQUIRES RESUBMIT |
| 05/12/2023 | RESTAMP - COMMERCIAL v.1 | 05/15/2023 | APPROVED |
| 05/03/2023 | COMMERCIAL REVIEW - FULL v.2 | 05/12/2023 | APPROVED |
Conditions
Permit Number - T22CM04386
Permit Status: Complete
Permit Description: TI: offices/rooms
| Date | Description | Comments |
|---|---|---|
| 08/04/2022 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. | |
| 08/04/2022 | SPECIAL INSPECTION IS REQUIRED FOR AIR BALANCE REPORT REQUIRED PRIOR TO FINAL INSPECTION. | |
| 08/05/2022 | Prior to permit issuance a General Contractor Letter (GCL) is required |
Outstanding Inspections
Permit Status: Complete
Permit Number: T22CM04386
Permite Description: TI: offices/rooms
Total Outstanding Inspections - 9
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/26/2022 | COT - LCME - Mechanical Above Ceiling | N/A | Not Ready | |
| 04/20/2023 | COT - LCEL - Electrical Final | N/A | Not Applicable | |
| 04/20/2023 | COT - HCBU - Interior Shear Bracing | N/A | Not Applicable | |
| 04/20/2023 | COT - LCPL - Plumbing Progress | N/A | Not Applicable | |
| 04/20/2023 | COT - LCEL - Electrical Progress | N/A | Not Applicable | |
| 04/20/2023 | COT - LCPL - Plumbing Intermediate | N/A | Not Applicable | |
| 04/20/2023 | COT - LCME - Mechanical Intermediate | N/A | Not Applicable | |
| 10/26/2022 | COT - LCME - Mechanical Final | N/A | Not Ready | |
| 10/26/2022 | COT - FCON - Fire - Final | N/A | Not Ready |
Completed Inspections
Permit Status: Complete
Permit Number: T22CM04386
Permit Description: TI: offices/rooms
Total Completed Inspections - 14
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/14/2023 | COT - LCBU - Framing | Passed | ||
| 03/27/2023 | COT - LCME - Mechanical Progress | Passed | ||
| 04/07/2023 | COT - LCBU - Building Above Ceiling | Passed | ||
| 04/20/2023 | COT - LCME - Mechanical Above Ceiling | Passed | ||
| 04/20/2023 | COT - LCEL - Electrical Intermediate | Passed | ||
| 04/20/2023 | COT - LCEL - Electrical Above Ceiling | Passed | ||
| 04/20/2023 | COT - LCPL - Plumbing Above Ceiling | Passed | ||
| 04/20/2023 | COT - LCME - Mechanical Final | Passed | ||
| 04/27/2023 | COT - LCPL - Plumbing Final | Passed | ||
| 05/04/2023 | COT - FCON - Fire - Final | Passed | ||
| 05/04/2023 | COT - LCBU - Building Progress | Passed | ||
| 05/04/2023 | COT - LCBU - Building Final | Passed | ||
| 05/04/2023 | COT - FCON - Alarm - Final | Passed | No Fire Alarm System | |
| 05/04/2023 | COT - FCON - Sprinkler - Final | Passed | Not a sprinklered building. |