Review Date Reviewer's Name Type of Review Description Status Comments
06/29/2022 ROBERT SHERRY WATER REVIEW Completed
06/30/2022 PCAMARE1 ENGINEERING REVIEW Passed
07/06/2022 IMONSHI1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Completed
07/06/2022 IMONSHI1 ZONING REVIEW Approved
07/08/2022 JVINCEN1 FIRE REVIEW Approved
07/14/2022 SAFEBUILT 2ND PARTY REVIEW REVIEW Reqs Change Activity Number: T22CM04386

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


STRUCTURAL REVIEW COMMENTS:
Approved


BUILDING REVIEW COMMENTS:
Denied
1. Sheet A0.1: Under the interior finish requirements section, there are other occupants listed. Additionally, under the general building summary box its states that there is no mix use but the non-separated mix use box states yes. Provide clarification if other uses are actually present and correlate all applicable requirements.
2. Sheet A0.1: The egress plan should be larger and more legible. The egress plan should include the location of all equipment and clearly label all rooms. Provide a clearer egress plan with all of requested information.
3. Sheet A0.1: The egress plan should indicate the location of all exit signage and egress illumination in accordance with Sections 1008 and 1013.
4. Sheet A0.1: The travel to exit #1 travels through an office. Traveling through intervening space is not permitted. Provide a correct exit travel in accordance with Section 1016.2.
5. Sheet A2.0: Provide labeling for all the existing spaces to ensure the correct occupant load has been calculated.


MECHANICAL REVIEW COMMENTS:
Approved

ELECTRICAL REVIEW COMMENTS
Approved

PLUMBING REVIEW COMMENTS:
Approved

If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
07/14/2022 VVERA1 OUT TO CUSTOMER Completed