Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T22CM02292
Permit Details
Apply Date:
03/30/2022
Applicant:
Cecil Baldwin
Description:
SFR
Permit Reviews
Permit Number - T22CM02292
Permit Status: In review
Permit Description: SFR
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
03/30/2022 | RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO | 05/11/2022 | COMPLETED |
09/20/2022 | RESUBMITTAL | 09/23/2022 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T22CM02292
Permit Status: In review
Permit Description: SFR
Total Outstanding Activity Conditions - 2
Date | Name |
---|---|
04/19/2022 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
04/19/2022 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
Conditions
Permit Number - T22CM02292
Permit Status: In review
Permit Description: SFR
Date | Description | Comments |
---|---|---|
09/23/2022 | A Pima County Wastewater sign off required prior to issuance of permit. | |
09/23/2022 | General Contractor Letter (GCL) or Owner/Builder Waiver required prior to permit issuance | |
02/07/2024 | Prior to Issuance: This project requires issuance of a Development Package (DP) permit prior to issuance of this permit. Prior to TCO/Final: This project requires full completion of a Development Package (DP) permit prior to Temporary C of O and/or final completion this permit. |
Outstanding Inspections
Permit Status: In Review
Permit Number: T22CM02292
Permite Description: SFR
Total Outstanding Inspections - 17
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/21/2022 | COT - LCPL - Plumbing Intermediate | N/A | Canceled | {Activity date: 09/21/2022; Status: Not Applicable; Inspector: KEN; Comment: Entered by KKARSEN1 - } |
09/21/2022 | RSME - Mechanical Progress | N/A | Canceled | {Activity date: 09/21/2022; Status: Not Applicable; Inspector: KEN; Comment: Entered by KKARSEN1 - } |
10/27/2022 | COT - RSME - Mechanical Final | N/A | Not Ready | |
10/27/2022 | RSBU - Building Final | N/A | Not Ready | |
10/26/2022 | COT - RSPL - Yard Water Line | N/A | Not Ready | |
10/27/2022 | COT - RSEL - Outdoor Lighting | N/A | Not Ready | |
10/27/2022 | COT - RSPL - Plumbing Final | N/A | Not Ready | |
10/26/2022 | COT - RSPL - Sewer | N/A | Not Ready | |
10/26/2022 | COT - RSEL - Construction Power | N/A | Not Ready | |
10/26/2022 | COT - RSPL - Rough Soil | N/A | Not Ready | |
10/26/2022 | COT - RSPL - Gas Pressure Test | N/A | Not Ready | |
10/27/2022 | COT - RSEL - Electrical Final | N/A | Not Ready | |
06/06/2024 | COT - RSBU - Exterior Clips/Sheathing | N/A | Re-inspection required | 6/6/24: no access to site. Called Danny (no answer). |
10/26/2022 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Not Ready | |
10/26/2022 | COT - RSBU - Preslab | N/A | Not Ready | |
10/26/2022 | COT - RSEL - Grounding/Bonding | N/A | Not Ready | |
08/01/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 8/1/24: seal all penetrations through top plate throughout, Register missing at bathroom, return air grills missing throughout, light fixture in shower above soffit, separate grounds from neutral at sub panel, revision required for changes made throughout, block registers on three sides, insulate pex outside thermal barrier, receptacles missing throughout, seal all penetrations through vapor barrier. DWV not under test, roof drains not under pressure. Fire blocking required throughout, vent at fireplace needs clearance from combustibles, More items may be added stopped inspection. |
Completed Inspections
Permit Status: In Review
Permit Number: T22CM02292
Permit Description: SFR
Total Completed Inspections - 10
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/29/2024 | COT - RSBU - Roof Nailing | Passed | ||
03/28/2024 | COT - RSEL - Electrical Underground | Passed | 200 amp service to.house. Ok to cover conduits. | |
08/01/2024 | COT - LCBU - Framing | Passed | 7/25/24: framing not per plan (missing shear walls, holdowns, anchor bolts, shot pins, fire blocking) throughout house. Framing at exterior columns passed ok to lath columns only. 8/1/24: corrections made ok to proceed. |
|
08/01/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | ||
08/01/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
08/01/2024 | COT - RSBU - Preslab | Passed | ||
08/01/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
08/09/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 8/1/24: seal all penetrations through top plate throughout, Register missing at bathroom, return air grills missing throughout, light fixture in shower above soffit, separate grounds from neutral at sub panel, revision required for changes made throughout, block registers on three sides, insulate pex outside thermal barrier, receptacles missing throughout, seal all penetrations through vapor barrier. DWV not under test, roof drains not under pressure. Fire blocking required throughout, vent at fireplace needs clearance from combustibles, More items may be added stopped inspection. 8/9/24: corrections made ok to proceed. |
|
08/27/2024 | BULD - Electrical Clearance | Passed | 8/27/24: ECO TEP clearance at 3137 W TUMAMOC DR | |
09/12/2024 | COT - HCBU - Interior Shear Bracing | Passed |