Permit: T22CM02292

Parcel: 116277690


Addresses:

3137 W TUMAMOC DR


Inspection Status: Not Ready

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Permit Number - T22CM02292

Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Inspection Status - Not Ready

Date Description Inspector Results Comments
10/26/2022 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Not Ready
08/01/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 8/1/24: seal all penetrations through top plate throughout, Register missing at bathroom, return air grills missing throughout, light fixture in shower above soffit, separate grounds from neutral at sub panel, revision required for changes made throughout, block registers on three sides, insulate pex outside thermal barrier, receptacles missing throughout, seal all penetrations through vapor barrier. DWV not under test, roof drains not under pressure. Fire blocking required throughout, vent at fireplace needs clearance from combustibles, More items may be added stopped inspection.
08/09/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 8/1/24: seal all penetrations through top plate throughout, Register missing at bathroom, return air grills missing throughout, light fixture in shower above soffit, separate grounds from neutral at sub panel, revision required for changes made throughout, block registers on three sides, insulate pex outside thermal barrier, receptacles missing throughout, seal all penetrations through vapor barrier. DWV not under test, roof drains not under pressure. Fire blocking required throughout, vent at fireplace needs clearance from combustibles, More items may be added stopped inspection.
8/9/24: corrections made ok to proceed.