Permit: T22CM01430
Permit Details
Status:
Issued
Type:
Residential Building - One or Two Family
Address:
6484 E VIA JARDIN VERDE
Address NEW:
6484 E VIA JARDIN VERDE
Apply Date:
02/28/2022
Applicant:
Description:
SFR RICHT908 T19-M0084
Outstanding Activity Conditions
Permit Number - T22CM01430
Permit Status: Issued
Permit Description: SFR RICHT908 T19-M0084
Total Outstanding Activity Conditions - 3
| Date | Name |
|---|---|
| 02/28/2022 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 02/28/2022 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
| 02/28/2022 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
Completed Inspections
Permit Status: Issued
Permit Number: T22CM01430
Permit Description: SFR RICHT908 T19-M0084
Total Completed Inspections - 23
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/08/2022 | COT - RSPL - Rough Soil | Passed | {Activity date: 04/08/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
| 05/03/2022 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 05/03/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 04/29/2022; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Not Ready Provide approved plan set and lot signs prior to inspection.} |
|
| 05/03/2022 | COT - RSBU - Preslab | Passed | {Activity date: 05/03/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 04/29/2022; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Not Ready Provide approved plan set and lot signs prior to inspection.} |
|
| 05/03/2022 | COT - RSPL - Yard Water Line | Passed | {Activity date: 05/03/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 04/29/2022; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Not Ready Provide approved plan set and lot signs prior to inspection.} |
|
| 05/03/2022 | COT - RSEL - Electrical Underground | Passed | {Activity date: 05/03/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 04/29/2022; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Not Ready Provide approved plan set and lot signs prior to inspection.} |
|
| 05/03/2022 | COT - RSPL - Sewer | Passed | {Activity date: 05/03/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
| 05/03/2022 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 05/03/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 04/29/2022; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Not Ready Provide approved plan set and lot signs prior to inspection.} |
|
| 05/17/2022 | COT - RSBU - Roof Nailing | Passed | {Activity date: 05/17/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
| 05/19/2022 | COT - LCBU - Framing | Passed | {Activity date: 05/19/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 05/17/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - CO} | |
| 05/19/2022 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | {Activity date: 05/19/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 05/17/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - . CO 1. Remove all nails into the bottom cord of trusses connecting to top plate. 2. Remove shims under girder at mid bearing point until dead load 3. 3 king studs required each end of patio opening. } |
|
| 09/16/2022 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 09/16/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CODD ECO} | |
| 09/16/2022 | COT - RSEL - Construction Power | Passed | {Activity date: 09/16/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP. TEP ECO} | |
| 09/16/2022 | COT - RSPL - Gas Pressure Test | Passed | {Activity date: 09/16/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
| 09/19/2022 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 09/19/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 09/16/2022; Status: Denied; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - DE 1. Seal penetrations in the lath 2. Reroute romex behind line set in wall 3. Secure gas line in the laundry 4. Move the smoke det more than 3 feet from bathroom door} |
|
| 09/19/2022 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 09/19/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 09/16/2022; Status: Denied; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - DE} | |
| 09/19/2022 | RSME - Mechanical Progress | Passed | {Activity date: 09/19/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 09/16/2022; Status: Denied; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - DE} | |
| 10/04/2022 | COT - HCBU - Interior Shear Bracing | Passed | {Activity date: 10/04/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
| 12/08/2022 | COT - BULD - SWG Clearance | Passed | clearance for Southwest Gas | |
| 02/23/2023 | RSBU - Building Final | Passed | ||
| 02/23/2023 | COT - RSEL - Outdoor Lighting | Passed | ||
| 02/23/2023 | COT - RSME - Mechanical Final | Passed | ||
| 02/23/2023 | COT - RSPL - Plumbing Final | Passed | ||
| 02/23/2023 | COT - RSEL - Electrical Final | Passed |