Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T22CM01430

Parcel: 141362400

Inspection Status: Passed

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
05/19/2022 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing TLUNDBERG Approved Entered by VVERA1 - AP
05/17/2022 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing TLUNDBERG Correction Required Entered by NGARCIA3 - . CO 1. Remove all nails into the bottom cord of trusses connecting to top plate. 2. Remove shims under girder at mid bearing point until dead load 3. 3 king studs required each end of patio opening.