| 05/19/2022 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
TLUNDBERG |
Approved |
Entered by VVERA1 - AP |
| 05/17/2022 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
TLUNDBERG |
Correction Required |
Entered by NGARCIA3 - . CO
1. Remove all nails into the bottom cord of trusses connecting to top plate.
2. Remove shims under girder at mid bearing point until dead load
3. 3 king studs required each end of patio opening.
|