Start Date | Submittal | Complete Date | Status |
---|---|---|---|
02/18/2022 | RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO | 06/08/2022 | COMPLETED |
06/15/2022 | RESUBMITTAL | 07/01/2022 | COMPLETED |
07/01/2022 | RESUBMITTAL | 07/06/2022 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T22CM01239
Permit Status: Issued
Permit Description: Addition and remodel of existing house. Remove existing carport replace with garage.
Total Outstanding Activity Conditions - 2
Date | Name |
---|---|
06/08/2022 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
06/08/2022 | SHOP DRAWINGS REQUIRED FOR PRE-MANUFACTURED TRUSSES |
Outstanding Inspections
Permit Status: Issued
Permit Number: T22CM01239
Permite Description: Addition and remodel of existing house. Remove existing carport replace with garage.
Total Outstanding Inspections - 7
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/26/2022 | COT - RSEL - Construction Power | N/A | Not Ready | |
10/26/2022 | COT - RSEL - Service Upgrade | N/A | Not Ready | |
10/26/2022 | COT - RSBU - Sustainability | N/A | Not Ready | |
01/05/2024 | COT - RSEL - Electrical Final | N/A | Not Ready | |
01/05/2024 | COT - RSPL - Plumbing Final | N/A | Not Ready | No gfi protection on island outlets and not located per plan, no gfi in laundry, hot and neutral reversed on kitchen gfi north unit, no cover on outlet under sink outlets in garage not complete, label garage |
01/05/2024 | COT - RSME - Mechanical Final | N/A | Not Ready | |
01/05/2024 | RSBU - Building Final | N/A | Not Ready |
Completed Inspections
Permit Status: Issued
Permit Number: T22CM01239
Permit Description: Addition and remodel of existing house. Remove existing carport replace with garage.
Total Completed Inspections - 20
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/14/2022 | COT - RSPL - Rough Soil | Passed | {Activity date: 09/14/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - approved. Okay to backfill. Shading is required.} ; {Activity date: 09/13/2022; Status: Cancelled; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Inspection canceled by contractor} | |
09/16/2022 | COT - RSBU - Preslab | Passed | {Activity date: 09/16/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VVERA1 - Approved} ; {Activity date: 09/14/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - not ready.} ; {Activity date: 09/13/2022; Status: Cancelled; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Inspection canceled by contractor} | |
09/16/2022 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 09/16/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VVERA1 - Approved} ; {Activity date: 09/14/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - not ready. Rebar needs to be clean and 3” above ground.} ; {Activity date: 09/13/2022; Status: Cancelled; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Inspection canceled by contractor} | |
09/19/2022 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 09/19/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - Approved} | |
03/16/2023 | COT - RSBU - Roof Nailing | Passed | Approved for both garage and two multi homes. 3/16/2023 | |
05/19/2023 | COT - LCBU - Framing | Passed | ||
05/19/2023 | COT - RSBU - Exterior Clips/Sheathing | Passed | ||
06/23/2023 | COT - BULD - SWG Clearance | Passed | Gas lines for 2109 & 2111 are under 15# of air pressure. Okay to install gas to structures. | |
06/23/2023 | COT - RSPL - Gas Pressure Test | Passed | Gas lines for 2109 & 2111 are under 15# of air pressure. Okay to install gas to structures. | |
06/23/2023 | RSEL - Electrical Progress | Passed | electrical rough-in is complete for 2109, 2111 & detached garage for both units. | |
06/23/2023 | BULD - Electrical Clearance | Passed | ECO CLEARANCE for addresses 2109 & 2111 E 2nd St meter boxes are on detached garage on rear of property. | |
06/28/2023 | COT - LCPL - Plumbing Intermediate | Passed | 6-28-23: DWV IS UNDER A WATER TEST with no leaks. Nail plates are installed on framing where needed to prevent damage to plumbing pipes. Okay to insulate, drywall, tape, and texture walls. | |
07/11/2023 | COT - HCBU - Interior Shear Bracing | Passed | Sheetrock nailing. Ok to tape throughout | |
09/06/2023 | COT - RSPL - Yard Water Line | Passed | Approved yard line from home to meter, okay to shade trench | |
10/27/2023 | COT - RSPL - Sewer | Passed | ||
01/10/2024 | COT - RSEL - Electrical Final | Passed | ||
01/10/2024 | RSME - Mechanical Progress | Passed | ||
01/10/2024 | COT - RSPL - Plumbing Final | Passed | ||
01/10/2024 | COT - RSME - Mechanical Final | Passed | ||
01/12/2024 | RSBU - Building Final | Passed |