Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T22CM01239

Parcel: 125041330


Addresses:

2109 E 2ND ST


Inspection Status: Not Ready

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - T22CM01239

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Not Ready

Date Description Inspector Results Comments
10/26/2022 COT - RSBU - Exterior Clips/Sheathing  Not Ready
10/26/2022 COT - RSBU - Exterior Clips/Sheathing  Not Ready
05/15/2023 COT - RSBU - Exterior Clips/Sheathing  Not Ready Not ready. Missing h25 clips at trusses in both multi homes. Missing anchor bolts at edges of bottom plates, some without nuts and washers. Add fire blocking 8' - 10'. Hangers in garage need to be nailed to joists. Nailing schedule on exterior should be 6" perimeter 12" on fields. 5/15/2023
COT - RSBU - Exterior Clips/Sheathing  Passed