Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Commercial Building
Address:
4420 N ORACLE RD
Address NEW:
4420 N ORACLE RD
Apply Date:
01/04/2022
Applicant:
Angel Martinez
Description:
REMODEL SIT DOWN EATING COUNTER INTO A BARAND ADDING EXTERIOR CANOPY

Permit Reviews

Permit Number - T22CM00044
Permit Status: Complete
Permit Description: REMODEL SIT DOWN EATING COUNTER INTO A BARAND ADDING EXTERIOR CANOPY
Start Date Submittal Complete Date Status  
01/04/2022 COMMERCIAL - BLDG/FIRE/ZONING/ENG 02/24/2022 COMPLETED Review Details
03/01/2022 RESUBMITTAL 03/14/2022 COMPLETED Review Details
10/03/2023 BUILDING DEFERRED SUBMITTAL REVIEW v.1 10/05/2023 APPROVED Review Details
09/18/2023 BUILDING DEFERRED SUBMITTAL REVIEW v.1 09/19/2023 APPROVED Review Details

Conditions

Permit Number - T22CM00044
Permit Status: Complete
Permit Description: REMODEL SIT DOWN EATING COUNTER INTO A BARAND ADDING EXTERIOR CANOPY
Date Description Comments
09/19/2023 AIR BALANCING/COMMISSIONING REPORT IS REQUIRED.
03/03/2022 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
03/03/2022 SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED.
03/03/2022 SPECIAL INSPECTION FOR WOOD FRAMED DIAPHRAGMS AND SHEAR WALLS IS REQUIRED.
03/03/2022 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
10/05/2023 COUNTY HEALTH INSPECTION IS REQUIRED - PLEASE PROVIDE DOCUMENTATION THAT THE INSPECTION HAS BEEN COMPLETED AND PASSED.

Outstanding Inspections

Permit Status: Complete
Permit Number: T22CM00044
Permite Description: REMODEL SIT DOWN EATING COUNTER INTO A BARAND ADDING EXTERIOR CANOPY
Total Outstanding Inspections - 14
Last Inspection Date Description Inspector Results Comments
10/27/2022 COT - LCBU - Framing N/A Not Ready
10/26/2022 COT - LCBU - Exterior Clips/Sheathing N/A Not Ready
08/22/2023 COT - LCBU - Building Progress N/A Not Applicable
08/22/2023 COT - LCEL - Service Upgrade N/A Not Applicable
08/22/2023 COT - LCBU - Roof Nailing N/A Not Applicable
11/10/2022 COT - LCEL - Electrical Progress N/A Partial Pass in-wall complete. above ceiling nr.
08/22/2023 COT - LCPL - Gas Pressure Test N/A Not Applicable
08/22/2023 COT - ENGR - Site - Assurance Release N/A Not Ready ADA compliance issues need resolution
08/22/2023 COT - LCEL - Electrical Final N/A Re-inspection required 8/22/23: 1. City of Tucson approved plans required on site. 2. Health Dept, Site Engineering, Fire Dept required to give final approval. 3. Install ADA restroom signage, sinks exceed 34" from floor, coat hooks required and not to exceed 48" from the floor, wrap all plumbing under the sinks, new mirror in men's restroom exceeds 40" from the floor, urinal in men's restroom exceeds 17" from the floor (only one is required to be compliant). 4. Several outlets within 60" of sinks are not GFCI protected, type all panel schedules and insert in clear plastic sleeve, remove all green tape and sharpie lettering from the deadfronts, blank cover over all open slots. 5. More items may be added when I review the approved plans.
10/26/2022 COT - FCON - Alarm - Final N/A Not Ready
10/26/2022 COT - FCON - Sprinkler - Final N/A Not Ready
09/22/2023 COT - FCON - Fire - Final N/A Partial Pass Need Places of Assembly permit, occupant load sign.
10/26/2022 COT - FCON - Hood System - Final N/A Not Ready
10/27/2022 COT - LCBU - Building Final N/A Not Ready

Completed Inspections

Permit Status: Complete
Permit Number: T22CM00044
Permit Description: REMODEL SIT DOWN EATING COUNTER INTO A BARAND ADDING EXTERIOR CANOPY
Total Completed Inspections - 16
Date Description Inspector Results Comments
11/10/2022 COT - LCPL - Plumbing Intermediate Passed potable and dwv ok to cover.
gas pressure test
gas line runs ok.
08/22/2023 COT - LCBU - Preslab Passed
08/22/2023 COT - LCEL - Electrical Intermediate Passed
08/22/2023 COT - LCEL - Electrical Above Ceiling Passed
09/22/2023 COT - LCPL - Plumbing Final Passed 9/22/23: all corrections made
09/22/2023 COT - ENGR - Site - Assurance Release Passed
09/22/2023 COT - LCEL - Electrical Final Passed 9/22/23: all corrections made
09/26/2023 COT - FCON - Alarm - Final Passed Approved on 9/11/23 on permit TF-FCP-0523-00680
09/26/2023 COT - FCON - Sprinkler - Final Passed Approved on 9/12/23 on permit TF-FCP-0423-00599
09/26/2023 COT - FCON - Fire - Final Passed
09/26/2023 COT - FCON - Hood System - Final Passed Approved on 9/19/23 on permit TF-FCP-0723-00886
09/27/2023 COT - LCBU - Building Final Passed
09/28/2023 COT - LCME - Mechanical Progress Passed
09/28/2023 COT - LCME - Mechanical Intermediate Passed
09/28/2023 COT - LCME - Mechanical Final Passed
09/28/2023 COT - LCPL - Plumbing Progress Passed

Documents

File Name Document Type  
COFO_FINALCOFO_COMMERCIAL.PDF DOCUMENTS VIEW
EPOXY - WELDING_V1.PDF DOCUMENTS VIEW
WELDING INSPECTION-2023-10-02_V1.PDF DOCUMENTS VIEW
WOOD LATERAL FORCE RESISTING SYSTEM_V1.PDF DOCUMENTS VIEW
CONS-TESORO LATIN CANTINA FLOOR - ROOF PLAN_V1.PDF DOCUMENTS VIEW
TESORO LATIN CANTINA - REPORT_V1.PDF DOCUMENTS VIEW
APPLICATION.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
JOB CARD.PDF DOCUMENTS VIEW
SPECIAL INSPECTION CERT.PDF DOCUMENTS VIEW
STRUCTURAL CALCULATIONS.PDF DOCUMENTS VIEW
PLAN SET.PDF CONSTRPLANS VIEW