Permit: T22CM00044
Permit Details
Apply Date:
01/04/2022
Applicant:
Angel Martinez
Description:
REMODEL SIT DOWN EATING COUNTER INTO A BARAND ADDING EXTERIOR CANOPY
Permit Reviews
Permit Number - T22CM00044
Permit Status: Complete
Permit Description: REMODEL SIT DOWN EATING COUNTER INTO A BARAND ADDING EXTERIOR CANOPY
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/04/2022 | COMMERCIAL - BLDG/FIRE/ZONING/ENG | 02/24/2022 | COMPLETED |
| 03/01/2022 | RESUBMITTAL | 03/14/2022 | COMPLETED |
| 10/03/2023 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 10/05/2023 | APPROVED |
| 09/18/2023 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 09/19/2023 | APPROVED |
Conditions
Permit Number - T22CM00044
Permit Status: Complete
Permit Description: REMODEL SIT DOWN EATING COUNTER INTO A BARAND ADDING EXTERIOR CANOPY
| Date | Description | Comments |
|---|---|---|
| 09/19/2023 | AIR BALANCING/COMMISSIONING REPORT IS REQUIRED. | |
| 03/03/2022 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. | |
| 03/03/2022 | SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED. | |
| 03/03/2022 | SPECIAL INSPECTION FOR WOOD FRAMED DIAPHRAGMS AND SHEAR WALLS IS REQUIRED. | |
| 03/03/2022 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
| 10/05/2023 | COUNTY HEALTH INSPECTION IS REQUIRED - PLEASE PROVIDE DOCUMENTATION THAT THE INSPECTION HAS BEEN COMPLETED AND PASSED. |
Outstanding Inspections
Permit Status: Complete
Permit Number: T22CM00044
Permite Description: REMODEL SIT DOWN EATING COUNTER INTO A BARAND ADDING EXTERIOR CANOPY
Total Outstanding Inspections - 14
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/27/2022 | COT - LCBU - Framing | N/A | Not Ready | |
| 10/26/2022 | COT - LCBU - Exterior Clips/Sheathing | N/A | Not Ready | |
| 08/22/2023 | COT - LCBU - Building Progress | N/A | Not Applicable | |
| 08/22/2023 | COT - LCEL - Service Upgrade | N/A | Not Applicable | |
| 08/22/2023 | COT - LCBU - Roof Nailing | N/A | Not Applicable | |
| 11/10/2022 | COT - LCEL - Electrical Progress | N/A | Partial Pass | in-wall complete. above ceiling nr. |
| 08/22/2023 | COT - LCPL - Gas Pressure Test | N/A | Not Applicable | |
| 08/22/2023 | COT - ENGR - Site - Assurance Release | N/A | Not Ready | ADA compliance issues need resolution |
| 08/22/2023 | COT - LCEL - Electrical Final | N/A | Re-inspection required | 8/22/23: 1. City of Tucson approved plans required on site. 2. Health Dept, Site Engineering, Fire Dept required to give final approval. 3. Install ADA restroom signage, sinks exceed 34" from floor, coat hooks required and not to exceed 48" from the floor, wrap all plumbing under the sinks, new mirror in men's restroom exceeds 40" from the floor, urinal in men's restroom exceeds 17" from the floor (only one is required to be compliant). 4. Several outlets within 60" of sinks are not GFCI protected, type all panel schedules and insert in clear plastic sleeve, remove all green tape and sharpie lettering from the deadfronts, blank cover over all open slots. 5. More items may be added when I review the approved plans. |
| 10/26/2022 | COT - FCON - Alarm - Final | N/A | Not Ready | |
| 10/26/2022 | COT - FCON - Sprinkler - Final | N/A | Not Ready | |
| 09/22/2023 | COT - FCON - Fire - Final | N/A | Partial Pass | Need Places of Assembly permit, occupant load sign. |
| 10/26/2022 | COT - FCON - Hood System - Final | N/A | Not Ready | |
| 10/27/2022 | COT - LCBU - Building Final | N/A | Not Ready |
Completed Inspections
Permit Status: Complete
Permit Number: T22CM00044
Permit Description: REMODEL SIT DOWN EATING COUNTER INTO A BARAND ADDING EXTERIOR CANOPY
Total Completed Inspections - 16
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/10/2022 | COT - LCPL - Plumbing Intermediate | Passed | potable and dwv ok to cover. gas pressure test gas line runs ok. |
|
| 08/22/2023 | COT - LCBU - Preslab | Passed | ||
| 08/22/2023 | COT - LCEL - Electrical Intermediate | Passed | ||
| 08/22/2023 | COT - LCEL - Electrical Above Ceiling | Passed | ||
| 09/22/2023 | COT - LCPL - Plumbing Final | Passed | 9/22/23: all corrections made | |
| 09/22/2023 | COT - ENGR - Site - Assurance Release | Passed | ||
| 09/22/2023 | COT - LCEL - Electrical Final | Passed | 9/22/23: all corrections made | |
| 09/26/2023 | COT - FCON - Alarm - Final | Passed | Approved on 9/11/23 on permit TF-FCP-0523-00680 | |
| 09/26/2023 | COT - FCON - Sprinkler - Final | Passed | Approved on 9/12/23 on permit TF-FCP-0423-00599 | |
| 09/26/2023 | COT - FCON - Fire - Final | Passed | ||
| 09/26/2023 | COT - FCON - Hood System - Final | Passed | Approved on 9/19/23 on permit TF-FCP-0723-00886 | |
| 09/27/2023 | COT - LCBU - Building Final | Passed | ||
| 09/28/2023 | COT - LCME - Mechanical Progress | Passed | ||
| 09/28/2023 | COT - LCME - Mechanical Intermediate | Passed | ||
| 09/28/2023 | COT - LCME - Mechanical Final | Passed | ||
| 09/28/2023 | COT - LCPL - Plumbing Progress | Passed |