Permit Details

Status:
In Review
Type:
Sign - Permanent
Address NEW:
10205 E OLD VAIL RD
Apply Date:
08/31/2021
Applicant:
Kelli Espinoza
Description:
2 freestanding signs (replace one off Houghton with larger sign, replace one off Old Vail) requires

Permit Reviews

Permit Number - T21OT00699
Permit Status: In review
Permit Description: 2 freestanding signs (replace one off Houghton with larger sign, replace one off Old Vail) requires
Start Date Submittal Complete Date Status  
12/14/2022 PERMANENT SIGN REVIEW v.1 12/15/2022 APPROVED Review Details

Outstanding Inspections

Permit Status: In Review
Permit Number: T21OT00699
Permite Description: 2 freestanding signs (replace one off Houghton with larger sign, replace one off Old Vail) requires
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
01/31/2022 COT - ENGR - Signage Final N/A Complete (Recurring) {Activity date: 01/31/2022; Status: Continued; Inspector: Hthrall1; Comment: Entered by HTHRALL1 - design professional MSP-21-09 / T21SA00374 reviewed, Director's Decision issued appeal ends 2/14/22.} ; {Activity date: 01/03/2022; Status: Continued; Inspector: Hthrall; Comment: Entered by HTHRALL1 - Contractor submitted revised plan set on 12/23/2021 - during holiday break. Review of permit package revision required prior to SDRC referral.} ; {Activity date: 12/03/2021; Status: Continued; Inspector: HThrall; Comment: Entered by HTHRALL1 - RE: Freestanding sign review (2 signs)
AT: 10205 E Old Vail Rd (Las Plazas at Old Vail / Houghton)
Sign permit: T21OT00699
Date: 09/20/21 & 12/3/21
Reviewer: H. Thrall

Codes: Unified Development Code Sign Standards 7A, National Electrical Code (NEC), Tucson-Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 2018

UDC comments:
Sign A:
A) Dimension all the black areas, as they are the cabinets for this sign.
B) Fix sign area conflicting notes on the plan
C) Sign A appears to Need **SDRC application to exceed max freedstanding sign allowed sign area in scenic for a sign not in the scenic buffer (exceed 50 sqf)-
D) Sign A appears to Need **SDRC application to exceed 50 square feet sign area for monument sign
E) Sign A appear to Need **SDRC application: Reduced setback off Old Vail for a monument sign less than 20' off arterial non-scenic street, sought at 14.34'.
F) Night view - tenants could have color or be white lettering only - i.e. logos ?

NEC / OLC
G) Add note - sign to use existing power (replacing smaller sign damaged /removed by car)
H) Add note for location of circuit breaker panel
I) Show lighting method for sconces (i.e. halo - colors, down light, what?) show on night view
IBC:
J) Thank you for engineering - will be examined further only should the SDRC case request be approved (review fees apply)
Sign B - 2nd sign - off Houghton
UDC comments:
1) Exceed sign area of 50 sqft not in the buffer - to approx. 71 (shows 10 panels - exceeds allowance of 8 panels max - + a site ID on it)
2) Exceed sign area of 50 sqft for a monument sign - general criteria
3) Cannot exceed 8 panels per MSP 7A.7.1. (and discussion with Zoning Administrator)
4) Exceed height of monument sign (general criteria) from 10' to 13.5' for monument to top of cabinet
5) Exceed height of a freestanding sign in scenic district
6) MAY need setback reduction - unclear (appears to use T17OT00875 location w/ 32' setback)
7) Need night view to show how lettering would be on sign
8) Need common background color for all - show designated background panel color (label if it will be white)- as current sign does not have that
NEC / OLC:
9) 4400k max color temp note needed page 14
10) Specify using existing electric, indicate where breaker panel is

IBC: Page 15:
11) Provide construction details for this sign expansion (i.e. cuts, welds, bolts, extensions, framework, etc.)
12) Engineering required for this sign structure - provide for review if the SDRC case is approved for an increase in size / max 8 panels.

13) Provide site plan for sign B location in comparison to current Houghton right of way.

Send revisions to Heather.Thrall@tucsonaz.gov
}

Completed Inspections

Permit Status: In Review
Permit Number: T21OT00699
Permit Description: 2 freestanding signs (replace one off Houghton with larger sign, replace one off Old Vail) requires
Total Completed Inspections - 1
Date Description Inspector Results Comments
02/01/2023 COT - ENGR - Sign Footing and Excavation Passed How foundations are good continue

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
MSP-21-09 DECISION SIGNED T21SA00374.PDF DOCUMENTS VIEW
T21OT00699_PLANS_LAS PLAZAS CORNER SIGN AND NORTH HOUGHTON SIGN.PDF DOCUMENTS VIEW