Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T21OT00699

Parcel: 141185890


Addresses:

10205 E OLD VAIL RD

Inspection Status: Complete (Recurring)

Inspection History: COT - ENGR - Signage Final

Date Description Inspector Results Comments
01/31/2022 COT - ENGR - Signage Final Hthrall1 Continued Entered by HTHRALL1 - design professional MSP-21-09 / T21SA00374 reviewed, Director's Decision issued appeal ends 2/14/22.
01/03/2022 COT - ENGR - Signage Final Hthrall Continued Entered by HTHRALL1 - Contractor submitted revised plan set on 12/23/2021 - during holiday break. Review of permit package revision required prior to SDRC referral.
12/03/2021 COT - ENGR - Signage Final HThrall Continued Entered by HTHRALL1 - RE: Freestanding sign review (2 signs) AT: 10205 E Old Vail Rd (Las Plazas at Old Vail / Houghton) Sign permit: T21OT00699 Date: 09/20/21 & 12/3/21 Reviewer: H. Thrall Codes: Unified Development Code Sign Standards 7A, National Electrical Code (NEC), Tucson-Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 2018 UDC comments: Sign A: A) Dimension all the black areas, as they are the cabinets for this sign. B) Fix sign area conflicting notes on the plan C) Sign A appears to Need **SDRC application to exceed max freedstanding sign allowed sign area in scenic for a sign not in the scenic buffer (exceed 50 sqf)- D) Sign A appears to Need **SDRC application to exceed 50 square feet sign area for monument sign E) Sign A appear to Need **SDRC application: Reduced setback off Old Vail for a monument sign less than 20' off arterial non-scenic street, sought at 14.34'. F) Night view - tenants could have color or be white lettering only - i.e. logos ? NEC / OLC G) Add note - sign to use existing power (replacing smaller sign damaged /removed by car) H) Add note for location of circuit breaker panel I) Show lighting method for sconces (i.e. halo - colors, down light, what?) show on night view IBC: J) Thank you for engineering - will be examined further only should the SDRC case request be approved (review fees apply) Sign B - 2nd sign - off Houghton UDC comments: 1) Exceed sign area of 50 sqft not in the buffer - to approx. 71 (shows 10 panels - exceeds allowance of 8 panels max - + a site ID on it) 2) Exceed sign area of 50 sqft for a monument sign - general criteria 3) Cannot exceed 8 panels per MSP 7A.7.1. (and discussion with Zoning Administrator) 4) Exceed height of monument sign (general criteria) from 10' to 13.5' for monument to top of cabinet 5) Exceed height of a freestanding sign in scenic district 6) MAY need setback reduction - unclear (appears to use T17OT00875 location w/ 32' setback) 7) Need night view to show how lettering would be on sign 8) Need common background color for all - show designated background panel color (label if it will be white)- as current sign does not have that NEC / OLC: 9) 4400k max color temp note needed page 14 10) Specify using existing electric, indicate where breaker panel is IBC: Page 15: 11) Provide construction details for this sign expansion (i.e. cuts, welds, bolts, extensions, framework, etc.) 12) Engineering required for this sign structure - provide for review if the SDRC case is approved for an increase in size / max 8 panels. 13) Provide site plan for sign B location in comparison to current Houghton right of way. Send revisions to Heather.Thrall@tucsonaz.gov