Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T21CM08759
Permit Details
Apply Date:
11/08/2021
Applicant:
Description:
SFR RICHT908 T19-M0084
Outstanding Activity Conditions
Permit Number - T21CM08759
Permit Status: Issued
Permit Description: SFR RICHT908 T19-M0084
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
11/08/2021 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
Completed Inspections
Permit Status: Issued
Permit Number: T21CM08759
Permit Description: SFR RICHT908 T19-M0084
Total Completed Inspections - 23
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/18/2021 | COT - RSPL - Yard Water Line | Passed | {Activity date: 11/18/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Approved} | |
11/18/2021 | COT - RSPL - Sewer | Passed | {Activity date: 11/18/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Approved} | |
11/18/2021 | COT - RSPL - Rough Soil | Passed | {Activity date: 11/18/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Approved} | |
11/24/2021 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 11/24/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Approved} | |
11/24/2021 | COT - RSBU - Preslab | Passed | {Activity date: 11/24/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Approved} | |
11/24/2021 | COT - RSEL - Electrical Underground | Passed | {Activity date: 11/24/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Approved} | |
11/24/2021 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 11/24/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Approved} | |
12/21/2021 | COT - RSBU - Roof Nailing | Passed | {Activity date: 12/21/2021; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 12/17/2021; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - CO.. corrections incomplete from 12/14 inspection. } ; {Activity date: 12/14/2021; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by RSALDAT1 - CO 1. Loose sheet on southeast area.} |
|
12/21/2021 | COT - RSBU - Exterior Clips/Sheathing | Passed | {Activity date: 12/21/2021; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 12/17/2021; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - CO None of the corrections have been made from the 12/14 inspection} ; {Activity date: 12/14/2021; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by RSALDAT1 - CO 1. Remove shims @ 2-ply girder truss mid-bearing point 2. Remove or attach loose metal bracing at top of trusses 3. Shear transfer to the roof is incomplete per detail 14/SD1.3c} |
|
01/26/2022 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 01/26/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CODE ECO} | |
01/26/2022 | COT - RSEL - Construction Power | Passed | {Activity date: 01/26/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP TEP ECO } |
|
04/19/2022 | COT - LCBU - Framing | Passed | {Activity date: 04/19/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
04/19/2022 | COT - RSPL - Gas Pressure Test | Passed | {Activity date: 04/19/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 04/18/2022; Status: Cancelled; Inspector: TGAUSP; Comment: Entered by VVERA1 - The following inspections are Cancelled, no response from Richmond American office 1080 (RESIDENTIAL INTERMEDIATE) 3035 (PLUMBING - INTERMEDIATE) 3050 (PLUMBING - GAS PRESSURE TEST) 4035 (MECHANICAL - INTERMEDIATE) } ; {Activity date: 04/13/2022; Status: Not ready for Inspection; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Not ready gas pressure low } |
|
04/25/2022 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 04/25/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 04/22/2022; Status: Denied; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - DE House insulated on a red tag. Remove all insulation from house. Cancel all other inspections} ; {Activity date: 04/19/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - CO. 1. Nail plate T&P line in garage 2. Burn in the line set 3. Block high/low vents in the garage 4. Repair excessive hole in roof at B-vent. 5. Secure gas line in laundry 6. Water test shower and nail plate vent above shower 7. Support both ends of 4-gang box 8. Refoam weep screed. Many gaps thruout} ; {Activity date: 04/18/2022; Status: Cancelled; Inspector: TGAUSP; Comment: Entered by VVERA1 - The following inspections are Cancelled, no response from Richmond American office 1080 (RESIDENTIAL INTERMEDIATE) 3035 (PLUMBING - INTERMEDIATE) 3050 (PLUMBING - GAS PRESSURE TEST) 4035 (MECHANICAL - INTERMEDIATE) } ; {Activity date: 04/15/2022; Status: Not ready for Inspection; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - NR 1. Block high/low vents 2. Relieve all truss mid-point bearing points, and detach H2.5 3. Block the hammered out hole in garage shear wall. 4. Block all registers on 3 sides INSPECTION STOPPED. THIS HOUSE IS NOT READY FOR INSPECTION } ; {Activity date: 04/13/2022; Status: Not ready for Inspection; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Not ready see 00035 results, several wires touching gussets } |
|
04/25/2022 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 04/25/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 04/22/2022; Status: Cancelled; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - } ; {Activity date: 04/19/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - CO} ; {Activity date: 04/18/2022; Status: Cancelled; Inspector: TGAUSP; Comment: Entered by VVERA1 - The following inspections are Cancelled, no response from Richmond American office 1080 (RESIDENTIAL INTERMEDIATE) 3035 (PLUMBING - INTERMEDIATE) 3050 (PLUMBING - GAS PRESSURE TEST) 4035 (MECHANICAL - INTERMEDIATE) } ; {Activity date: 04/13/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Partial approval several pex lines touching metal gussets, no DWV TEST } |
|
04/25/2022 | RSME - Mechanical Progress | Passed | {Activity date: 04/25/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 04/22/2022; Status: Cancelled; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - } ; {Activity date: 04/19/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - CO} ; {Activity date: 04/18/2022; Status: Cancelled; Inspector: TGAUSP; Comment: Entered by VVERA1 - The following inspections are Cancelled, no response from Richmond American office 1080 (RESIDENTIAL INTERMEDIATE) 3035 (PLUMBING - INTERMEDIATE) 3050 (PLUMBING - GAS PRESSURE TEST) 4035 (MECHANICAL - INTERMEDIATE) } ; {Activity date: 04/13/2022; Status: Not ready for Inspection; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Not ready installation in progress not complete } |
|
05/09/2022 | COT - HCBU - Interior Shear Bracing | Passed | {Activity date: 05/09/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} ; {Activity date: 05/06/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - CO Maintain 3/8" distance of nails/screws to edge of wallboard} |
|
06/17/2022 | COT - RSPL - Plumbing Final | Passed | {Activity date: 06/17/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP SWG clearance required.} |
|
06/17/2022 | COT - BULD - SWG Clearance | Passed | {Activity date: 06/17/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - CODE GAS} | |
06/28/2022 | COT - RSME - Mechanical Final | Passed | {Activity date: 06/28/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
06/28/2022 | RSBU - Building Final | Passed | {Activity date: 06/28/2022; Status: Partial Approval; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - APPROVED BY INSPECTOR AWAITING CONDITIONS} ; {Activity date: 06/28/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
06/28/2022 | COT - RSEL - Outdoor Lighting | Passed | {Activity date: 06/28/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
06/28/2022 | COT - RSEL - Electrical Final | Passed | {Activity date: 06/28/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} |