Permit: T21CM08759

Parcel: 141410070

Inspection Status: Passed

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Permit Number - T21CM08759

Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Inspection Status - Passed

Date Description Inspector Results Comments
04/25/2022 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. ESTEVENS Approved Entered by NGARCIA3 - Approved
04/22/2022 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. TLUNDBERG Denied Entered by NGARCIA3 - DE House insulated on a red tag. Remove all insulation from house. Cancel all other inspections
04/19/2022 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. TLUNDBERG Correction Required Entered by NGARCIA3 - CO. 1. Nail plate T&P line in garage 2. Burn in the line set 3. Block high/low vents in the garage 4. Repair excessive hole in roof at B-vent. 5. Secure gas line in laundry 6. Water test shower and nail plate vent above shower 7. Support both ends of 4-gang box 8. Refoam weep screed. Many gaps thruout
04/18/2022 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. TGAUSP Cancelled Entered by VVERA1 - The following inspections are Cancelled, no response from Richmond American office 1080 (RESIDENTIAL INTERMEDIATE) 3035 (PLUMBING - INTERMEDIATE) 3050 (PLUMBING - GAS PRESSURE TEST) 4035 (MECHANICAL - INTERMEDIATE)
04/15/2022 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. TLUNDBERG Not ready for Inspection Entered by VVERA1 - NR 1. Block high/low vents 2. Relieve all truss mid-point bearing points, and detach H2.5 3. Block the hammered out hole in garage shear wall. 4. Block all registers on 3 sides INSPECTION STOPPED. THIS HOUSE IS NOT READY FOR INSPECTION
04/13/2022 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. WGALLAGHER Not ready for Inspection Entered by VVERA1 - Not ready see 00035 results, several wires touching gussets