Permit: T21CM08585
Permit Details
Apply Date:
11/01/2021
Applicant:
Description:
Ramada with Storage Building
Permit Reviews
Permit Number - T21CM08585
Permit Status: Complete
Permit Description: Ramada with Storage Building
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/25/2022 | RESUBMITTAL | 04/20/2022 | COMPLETED |
| 05/12/2022 | RESUBMITTAL | 05/19/2022 | COMPLETED |
| 06/04/2022 | RESUBMITTAL | 06/15/2022 | COMPLETED |
| 11/01/2021 | COMMERCIAL - BLDG/FIRE/ZONING/ENG | 12/08/2021 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T21CM08585
Permit Status: Complete
Permit Description: Ramada with Storage Building
Total Outstanding Activity Conditions - 8
| Date | Name |
|---|---|
| 06/14/2022 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 06/14/2022 | SPECIAL INSPECTION FOR CONCRETE IS REQUIRED.. |
| 06/14/2022 | SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED. |
| 06/14/2022 | SPECIAL INSPECTION FOR WELD REINF STEEL IS REQUIRED. |
| 06/14/2022 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 06/14/2022 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
| 06/15/2022 | This building permit approval is without public sewer connection review or approval. It is strictly the responsibility of the owner and/or person doing the work to ensure that the appropriate review and approval to connect is obtained from Regional Wastewater Reclamation Department (RWRD) wastewater provider or Pima County DEQ approval of/and alternative disposal system. It is required that owner and/or person doing the work solicit all requisite approvals from the wastewater provider prior to obtaining this building construction permit. RWRD connection information is available at www.pima.gov/wwm/developer.htm |
| 12/12/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
Outstanding Inspections
Permit Status: Complete
Permit Number: T21CM08585
Permite Description: Ramada with Storage Building
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/26/2022 | COT - LCPL - Plumbing Final | N/A | Not Ready | |
| 10/26/2022 | COT - FCON - Alarm - Final | N/A | Not Ready | |
| 10/26/2022 | COT - FCON - Sprinkler - Final | N/A | Not Ready | |
| 06/20/2023 | COT - LCEL - Outdoor Lighting | N/A | Partial Pass | 6-20-24: UG conduits |
Completed Inspections
Permit Status: Complete
Permit Number: T21CM08585
Permit Description: Ramada with Storage Building
Total Completed Inspections - 21
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/29/2023 | COT - LCBU - Excavation/Rebar/Zoning | Passed | ||
| 08/29/2023 | COT - LCBU - Preslab | Passed | ||
| 09/06/2023 | COT - LCBU - Exterior Clips/Sheathing | Passed | ||
| 09/06/2023 | COT - LCBU - Roof Nailing | Passed | ||
| 09/06/2023 | COT - LCBU - Framing | Passed | ||
| 10/11/2023 | COT - LCEL - Electrical Intermediate | Passed | ||
| 10/17/2023 | COT - HCBU - Interior Shear Bracing | Passed | ||
| 11/08/2023 | COT - LCEL - Electrical Underground | Passed | 11/7/23: partial pass pillars at rear of property (3 total) okay to pour concrete re inspection needed for pillar at front of property missing 20' of ground wire and not deep enough 11/8/23: corrections made. |
|
| 01/16/2024 | COT - LCBU - Building Final | Passed | ||
| 01/16/2024 | COT - LCEL - Electrical Final | Passed | ||
| 02/14/2024 | COT - LCPL - Plumbing Final | Passed | ||
| 02/14/2024 | COT - LCBU - Building Progress | Passed | ||
| 02/14/2024 | COT - LCME - Mechanical Progress | Passed | ||
| 02/14/2024 | COT - LCME - Mechanical Intermediate | Passed | ||
| 02/14/2024 | COT - LCBU - Building Above Ceiling | Passed | ||
| 02/14/2024 | COT - LCPL - Plumbing Intermediate | Passed | ||
| 02/14/2024 | COT - LCME - Mechanical Final | Passed | ||
| 02/14/2024 | COT - FCON - Fire - Final | Passed | ||
| 02/14/2024 | COT - LCEL - Electrical Progress | Passed | ||
| 02/14/2024 | COT - LCEL - Electrical Above Ceiling | Passed | ||
| 02/14/2024 | COT - LCEL - Outdoor Lighting | Passed |