Permit Details

Status:
Complete
Type:
Commercial Building
Address NEW:
1355 W ROGER RD BLDG 8
Apply Date:
10/01/2021
Applicant:
Peter Meyer
Description:
Bldg 8Remodel of 96 apartments located in 12 buildings plus remodel of community building.

Permit Reviews

Permit Number - T21CM07854
Permit Status: Complete
Permit Description: Bldg 8Remodel of 96 apartments located in 12 buildings plus remodel of community building.
Start Date Submittal Complete Date Status  
10/01/2021 3RD PARTY REVIEW - COMMERCIAL TI 12/23/2021 COMPLETED Review Details
12/15/2021 RESUBMITTAL 12/23/2021 COMPLETED Review Details

Conditions

Permit Number - T21CM07854
Permit Status: Complete
Permit Description: Bldg 8Remodel of 96 apartments located in 12 buildings plus remodel of community building.
Date Description Comments
12/10/2021 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Complete
Permit Number: T21CM07854
Permite Description: Bldg 8Remodel of 96 apartments located in 12 buildings plus remodel of community building.
Total Outstanding Inspections - 9
Last Inspection Date Description Inspector Results Comments
10/26/2022 COT - LCEL - Electrical Intermediate N/A Not Ready
10/27/2022 COT - LCPL - Plumbing Intermediate N/A Not Ready
10/26/2022 COT - LCME - Mechanical Intermediate N/A Not Ready
10/27/2022 COT - LCBU - Framing N/A Not Ready
08/31/2023 COT - LCEL - Electrical Reconnect N/A Not Applicable
08/31/2023 COT - LCME - Mechanical Final N/A Partial Pass 8/31/23: units 8132, 8131, 8129, and 8130 have AC units that are being over Amped by 30Amp fuses ( Max fuse is 25Amp), secure all electrical whips at rooftop AC units, AC units need condensate piping to be coated to prevent sun damage, All refrigerant lines on units 8129,8130,8131,8132 need to be coated to prevent sun damage on insulation. Receptacle on roof top needs to be WR and be provided with Weather cover, Junction box at roof top needs cover, Unit 3230 is missing cover at disconnect box, remove all excess conduit and wires on roof top.
08/31/2023 COT - LCPL - Plumbing Final N/A Partial Pass 8/31/23: units 8132, 8131, 8129, and 8130 have AC units that are being over Amped by 30Amp fuses ( Max fuse is 25Amp), secure all electrical whips at rooftop AC units, AC units need condensate piping to be coated to prevent sun damage, All refrigerant lines on units 8129,8130,8131,8132 need to be coated to prevent sun damage on insulation. Receptacle on roof top needs to be WR and be provided with Weather cover, Junction box at roof top needs cover, Unit 3230 is missing cover at disconnect box, remove all excess conduit and wires on roof top.
08/31/2023 COT - LCBU - Building Final N/A Partial Pass 8/31/23: units 8132, 8131, 8129, and 8130 have AC units that are being over Amped by 30Amp fuses ( Max fuse is 25Amp), secure all electrical whips at rooftop AC units, AC units need condensate piping to be coated to prevent sun damage, All refrigerant lines on units 8129,8130,8131,8132 need to be coated to prevent sun damage on insulation. Receptacle on roof top needs to be WR and be provided with Weather cover, Junction box at roof top needs cover, Unit 3230 is missing cover at disconnect box, remove all excess conduit and wires on roof top.
11/02/2023 BULD - Electrical Clearance N/A Not Applicable

Completed Inspections

Permit Status: Complete
Permit Number: T21CM07854
Permit Description: Bldg 8Remodel of 96 apartments located in 12 buildings plus remodel of community building.
Total Completed Inspections - 15
Date Description Inspector Results Comments
06/14/2023 COT - LCEL - Electrical Intermediate Passed
06/14/2023 COT - LCPL - Plumbing Intermediate Passed
06/14/2023 COT - LCME - Mechanical Intermediate Passed
06/14/2023 COT - LCEL - Electrical Above Ceiling Passed
06/14/2023 COT - LCBU - Framing Passed
07/12/2023 COT - LCEL - Grounding/Bonding Passed Approved grounding for 600A 8-pack meter at building 8
08/31/2023 COT - LCBU - Building Progress Passed
08/31/2023 COT - LCPL - Plumbing Above Ceiling Passed
08/31/2023 COT - LCME - Mechanical Above Ceiling Passed
08/31/2023 COT - LCEL - Electrical Final Passed 8/31/23: units 8132, 8131, 8129, and 8130 have AC units that are being over Amped by 30Amp fuses ( Max fuse is 25Amp), secure all electrical whips at rooftop AC units, AC units need condensate piping to be coated to prevent sun damage, All refrigerant lines on units 8129,8130,8131,8132 need to be coated to prevent sun damage on insulation. Receptacle on roof top needs to be WR and be provided with Weather cover, Junction box at roof top needs cover, Unit 3230 is missing cover at disconnect box, remove all excess conduit and wires on roof top.
10/10/2023 COT - HCBU - Interior Shear Bracing Passed
10/17/2023 COT - LCME - Mechanical Final Passed
10/17/2023 COT - LCPL - Plumbing Final Passed
10/17/2023 COT - LCBU - Building Final Passed
11/02/2023 COT - LCEL - Outdoor Lighting Passed

Documents

File Name Document Type  
LOFC_LETTEROFCOMPLETION.PDF DOCUMENTS VIEW
LOFC_LETTEROFCOMPLETION.PDF DOCUMENTS VIEW
APPLICATION.PDF DOCUMENTS VIEW
CALCS - STAIR RAILING.PDF DOCUMENTS VIEW
CALCS - STRUCTURAL.PDF DOCUMENTS VIEW
CALCS - STAIR RAILING.PDF DOCUMENTS VIEW
PSA.PDF DOCUMENTS VIEW
PLAN SET.PDF CONSTRPLANS VIEW
PERMIT_T21CM07854.PDF DOCUMENTS VIEW
JOB CARD_T21CM07854.PDF CONSTRPLANS VIEW