Permit: T21CM05008
Permit Details
Status:
Issued
Type:
Residential Building - One or Two Family
Address:
25 W LALO WY
Address NEW:
25 W LALO WY
Apply Date:
06/15/2021
Applicant:
Dan Kishinami
Description:
New Townhome
Permit Reviews
Permit Number - T21CM05008
Permit Status: Issued
Permit Description: New Townhome
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/15/2021 | 3RD PARTY REVIEW - RESIDENTIAL | 08/04/2021 | COMPLETED |
| 08/19/2021 | RESUBMITTAL | 10/04/2021 | COMPLETED |
| 08/13/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 08/15/2025 | APPROVED |
| 04/28/2023 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 05/01/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - T21CM05008
Permit Status: Issued
Permit Description: New Townhome
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/17/2025 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ |
Conditions
Permit Number - T21CM05008
Permit Status: Issued
Permit Description: New Townhome
| Date | Description | Comments |
|---|---|---|
| 01/17/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. |
Outstanding Inspections
Permit Status: Issued
Permit Number: T21CM05008
Permite Description: New Townhome
Total Outstanding Inspections - 15
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/27/2022 | RSBU - Building Final | N/A | Not Ready | |
| 10/27/2022 | COT - RSEL - Outdoor Lighting | N/A | Not Ready | |
| 10/26/2022 | COT - LCPL - Plumbing Above Ceiling | N/A | Not Ready | |
| 10/26/2022 | COT - LCBU - Sustainability | N/A | Not Ready | |
| 10/26/2022 | COT - RSEL - Construction Power | N/A | Not Ready | |
| 03/22/2023 | COT - RSEL - Electrical Underground | N/A | Partial Pass | |
| 01/12/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Partial Pass | Building progress only. |
| 08/07/2023 | COT - LCPL - Plumbing Intermediate | N/A | Partial Pass | 8/7/23: YWL inspections need tracer wire |
| 05/08/2024 | RSEL - Electrical Progress | N/A | Partial Pass | This inspection should read ELECTRIC INTERMEDIATE: Passed |
| 10/27/2022 | RSME - Mechanical Progress | N/A | Not Ready | |
| 07/27/2023 | COT - RSBU - Firewall/Fire Barrier/Firestop | N/A | Not Ready | 7/27/23: Not ready |
| 09/20/2024 | BULD - Electrical Clearance | N/A | Re-inspection required | 9/20/24: grounds and neutrals must be separated at sub-panels. NFPA 70 . NEC 250.142. |
| 12/02/2025 | COT - RSEL - Electrical Final | N/A | Re-inspection required | 12/2/25: GFCI required at laundry/water heater room, GFCI not working at second floor bathroom, open chase at mechanical room, disconnect clearance required at mechanical room, pain clean out on exterior, knock out at mechanical room, leak repair behind refrigerator, microwave receptacle must have cover plate and cannot be further than 1/4" behind combustible material, kitchen exhaust not complete, appliances must be installed, receptacle cover plate required at garage, arc-fault required at laundry room breaker, receptacle at roof keeps tripping,supports required at refrigerant lines at roof, |
| 12/02/2025 | COT - RSME - Mechanical Final | N/A | Re-inspection required | 12/2/25: GFCI required at laundry/water heater room, GFCI not working at second floor bathroom, open chase at mechanical room, disconnect clearance required at mechanical room, pain clean out on exterior, knock out at mechanical room, leak repair behind refrigerator, microwave receptacle must have cover plate and cannot be further than 1/4" behind combustible material, kitchen exhaust not complete, appliances must be installed, receptacle cover plate required at garage, arc-fault required at laundry room breaker, receptacle at roof keeps tripping,supports required at refrigerant lines at roof, |
| 12/02/2025 | COT - RSPL - Plumbing Final | N/A | Re-inspection required | 12/2/25: GFCI required at laundry/water heater room, GFCI not working at second floor bathroom, open chase at mechanical room, disconnect clearance required at mechanical room, pain clean out on exterior, knock out at mechanical room, leak repair behind refrigerator, microwave receptacle must have cover plate and cannot be further than 1/4" behind combustible material, kitchen exhaust not complete, appliances must be installed, receptacle cover plate required at garage, arc-fault required at laundry room breaker, receptacle at roof keeps tripping,supports required at refrigerant lines at roof, |
Completed Inspections
Permit Status: Issued
Permit Number: T21CM05008
Permit Description: New Townhome
Total Completed Inspections - 12
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/10/2022 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 08/10/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - approved} | |
| 08/24/2022 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 08/24/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by VVERA1 - Approved} ; {Activity date: 08/10/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - approved} | |
| 12/27/2022 | COT - RSPL - Rough Soil | Passed | ||
| 12/27/2022 | COT - RSPL - Sewer | Passed | ||
| 02/07/2023 | COT - RSBU - Preslab | Passed | Excavation/layout-rebar for step down between buildings A & B. | |
| 07/27/2023 | RSBU - Building Progress | Passed | ||
| 08/11/2023 | COT - RSPL - Yard Water Line | Passed | 8/11/2023 Approved. Okay to backfill shading required. | |
| 03/22/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | Ok to cover exterior walls. | |
| 04/11/2024 | COT - LCBU - Framing | Passed | ||
| 04/18/2024 | COT - LCPL - Plumbing Intermediate | Passed | ||
| 07/08/2024 | COT - RSBU - Firewall/Fire Barrier/Firestop | Passed | ||
| 09/26/2024 | BULD - Electrical Clearance | Passed | Ok to set meter for new service. |