Permit: T21CM05008

Parcel: 117073610


Addresses:

25 W LALO WY


Inspection Status: Not Ready

Inspection History: COT - RSME - Mechanical Final 

Permit Number - T21CM05008

Inspection Description - COT - RSME - Mechanical Final 

Inspection Status - Not Ready

Date Description Inspector Results Comments
10/27/2022 COT - RSME - Mechanical Final  Not Ready
12/02/2025 COT - RSME - Mechanical Final  Re-inspection required 12/2/25: GFCI required at laundry/water heater room, GFCI not working at second floor bathroom, open chase at mechanical room, disconnect clearance required at mechanical room, pain clean out on exterior, knock out at mechanical room, leak repair behind refrigerator, microwave receptacle must have cover plate and cannot be further than 1/4" behind combustible material, kitchen exhaust not complete, appliances must be installed, receptacle cover plate required at garage, arc-fault required at laundry room breaker, receptacle at roof keeps tripping,supports required at refrigerant lines at roof,