Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T21CM03291
Permit Details
Apply Date:
04/19/2021
Applicant:
Bryon Peel-Davis
Description:
Instrumentation/control upgrade including new vault and control building.CDRC indicated that no Spe
Permit Reviews
Permit Number - T21CM03291
Permit Status: Issued
Permit Description: Instrumentation/control upgrade including new vault and control building.CDRC indicated that no Spe
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/19/2021 | COMMERCIAL - TI | 06/03/2021 | COMPLETED |
06/03/2021 | COMMERCIAL - TI | 07/19/2021 | COMPLETED |
08/16/2021 | RESUBMITTAL | 08/26/2021 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T21CM03291
Permit Status: Issued
Permit Description: Instrumentation/control upgrade including new vault and control building.CDRC indicated that no Spe
Total Outstanding Activity Conditions - 6
Date | Name |
---|---|
05/04/2021 | SPECIAL INSPECTION FORMS AND REPORTS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY. |
05/04/2021 | SPECIAL INSPECTION FOR CONCRETE IS REQUIRED.. |
05/04/2021 | SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED. |
05/04/2021 | SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED. |
06/15/2021 | SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED. |
06/15/2021 | SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED. |
Outstanding Inspections
Permit Status: Issued
Permit Number: T21CM03291
Permite Description: Instrumentation/control upgrade including new vault and control building.CDRC indicated that no Spe
Total Outstanding Inspections - 7
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/05/2022 | COT - LCEL - Temporary Service | N/A | Canceled | {Activity date: 04/05/2022; Status: Not Applicable; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - not applicable } |
11/04/2022 | COT - LCBU - Building Final | N/A | Canceled | Inspection Canceled |
11/04/2022 | COT - LCME - Mechanical Final | N/A | Canceled | Inspection Canceled |
11/04/2022 | COT - LCEL - Outdoor Lighting | N/A | Canceled | Inspection Canceled |
11/04/2022 | COT - FCON - Fire - Final | N/A | Canceled | Inspection Canceled |
11/04/2022 | COT - LCME - Mechanical Intermediate | N/A | Canceled | Inspection Canceled |
11/07/2022 | COT - LCEL - Electrical Underground | N/A | Canceled | Inspection Canceled |
Completed Inspections
Permit Status: Issued
Permit Number: T21CM03291
Permit Description: Instrumentation/control upgrade including new vault and control building.CDRC indicated that no Spe
Total Completed Inspections - 13
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/13/2022 | COT - LCEL - Grounding/Bonding | Passed | {Activity date: 01/13/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved, EGC connections to ground ring for control room equipment complete. } ; {Activity date: 01/03/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by VVERA1 - Approved, 3-O copper ring and grid} |
|
01/25/2022 | COT - LCBU - Excavation/Rebar/Zoning | Passed | {Activity date: 01/25/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved, Control room slab re enforcement installed and ok for concrete placement.} ; {Activity date: 01/13/2022; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - PARTIAL, Inspection for Control Room footings F1, OK for concrete placement. Note: required special inspection report for Masonry Control Joints that were missing, and spoil clean out prior to concrete.} | |
01/25/2022 | COT - LCBU - Preslab | Passed | {Activity date: 01/25/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved, Control room slab ok for concrete placement.} ; {Activity date: 01/13/2022; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - NOT READY. } |
|
02/02/2022 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 02/02/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - CODE ECO} | |
02/02/2022 | COT - LCEL - Construction Power | Passed | {Activity date: 02/02/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved, clear TEP ECO} | |
04/05/2022 | COT - LCBU - Stem Wall/Retaining Wall | Passed | {Activity date: 04/05/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} | |
04/05/2022 | COT - LCEL - Electrical Progress | Passed | {Activity date: 04/05/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} | |
04/05/2022 | COT - LCEL - Electrical Intermediate | Passed | {Activity date: 04/05/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 03/11/2022; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Partial, Inspection of Booster Control panels, Feeders, and PLC Connections-in Control room ok to proceed. } |
|
04/05/2022 | COT - LCBU - Framing | Passed | {Activity date: 04/05/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} | |
04/05/2022 | COT - LCEL - Electrical Above Ceiling | Passed | {Activity date: 04/05/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} | |
04/05/2022 | COT - LCBU - Building Progress | Passed | {Activity date: 04/05/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} | |
04/05/2022 | COT - LCBU - Masonry Pregrout | Passed | {Activity date: 04/05/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} | |
11/04/2022 | COT - LCEL - Electrical Final | Passed | Approved, pending all other final inspections |