Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
Barricade and Excavation
Address:
330 E CORONA RD
Apply Date:
04/10/2020
Applicant:
COX COMMUNICATIONS
Description:
From the TEP pole East of 330 E Corona Rd, begin 854' aerial overlash adding 288ct fiber, heading East, continue 1389' aerial overlash heading South to out of ROW 05/15/2020 - PLAN CHANGE - R1- From the TEP pole East of 330 E Corona Rd, riser down and begin 854' trench/bore, placing 2-2'' conduit , heading East, continue 40' trench/bore heading South, riser up and begin 1349' aerial overlash heading South to out of ROW 06/18/202- - PLAN CHANGE R2 From the TEP pole East of 330 E Corona Rd, riser down and begin 854' trench/bore, placing 2-2'' conduit , heading East, continue 40' trench/bore heading South, riser up and begin 255' aerial overlash, riser down and begin 262' trench/bore heading South to out of ROW NOTES: Nogales Hwy was restored by the "Prop 409 Residential Streets", any new asphalt that is disturbed will require a 2" mill and overlay for 50' in each direction from the outside of the cut for all effected travel lanes. Maintain Ingress/ Egress access off of Corona Rd. and also along Nogales Hwy, for the business at 7130 S. Nogales Hwy
Contractors:
  • DESERT BARRICADES L L C
  • OPTIMUM AZ INC

Outstanding Inspections

Permit Status: Final
Permit Number: T20RW02068
Permite Description: From the TEP pole East of 330 E Corona Rd, begin 854' aerial overlash adding 288ct fiber, heading East, continue 1389' aerial overlash heading South to out of ROW 05/15/2020 - PLAN CHANGE - R1- From the TEP pole East of 330 E Corona Rd, riser down and begin 854' trench/bore, placing 2-2'' conduit , heading East, continue 40' trench/bore heading South, riser up and begin 1349' aerial overlash heading South to out of ROW 06/18/202- - PLAN CHANGE R2 From the TEP pole East of 330 E Corona Rd, riser down and begin 854' trench/bore, placing 2-2'' conduit , heading East, continue 40' trench/bore heading South, riser up and begin 255' aerial overlash, riser down and begin 262' trench/bore heading South to out of ROW NOTES: Nogales Hwy was restored by the "Prop 409 Residential Streets", any new asphalt that is disturbed will require a 2" mill and overlay for 50' in each direction from the outside of the cut for all effected travel lanes. Maintain Ingress/ Egress access off of Corona Rd. and also along Nogales Hwy, for the business at 7130 S. Nogales Hwy
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
07/14/2020 TDOT-EXCAV GENERAL INSPECTION N/A Continued No work

Documents

File Name Document Type  
T20RW02068 R1.PDF ROW-RIGHT OF WAY VIEW
T20RW02068 R2.PDF ROW-RIGHT OF WAY VIEW
T20RW02068 R3.PDF ROW-RIGHT OF WAY VIEW
T20RW02068.PDF ROW-RIGHT OF WAY VIEW