Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Sign - Permanent
Address NEW:
9191 E TANQUE VERDE RD
Apply Date:
03/09/2020
Applicant:
Jose Villanueva
Description:
(REVISED PLANS APPROVED 06/18/21 - REMOVE EXISTING 10' TALL MONUMENT - INSTALL NEW MONUMENT 6 FEET T

Outstanding Inspections

Permit Status: Complete
Permit Number: T20OT00215
Permite Description: (REVISED PLANS APPROVED 06/18/21 - REMOVE EXISTING 10' TALL MONUMENT - INSTALL NEW MONUMENT 6 FEET T
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
10/27/2022 COT - ENGR - Signage Final N/A Not Ready

Completed Inspections

Permit Status: Complete
Permit Number: T20OT00215
Permit Description: (REVISED PLANS APPROVED 06/18/21 - REMOVE EXISTING 10' TALL MONUMENT - INSTALL NEW MONUMENT 6 FEET T
Total Completed Inspections - 2
Date Description Inspector Results Comments
06/18/2021 SPECIAL INSPECTION - Sign Footing (Third Party) Passed {Activity date: 06/18/2021; Status: Continued; Inspector: Hthrall; Comment: Entered by HTHRALL1 - please call in for excavation} ; {Activity date: 06/18/2021; Status: Approved; Inspector: Hthrall; Comment: Entered by HTHRALL1 - Per Director S. Clark - revised plans approved, submitted to show a revised sign height lowered to 6 feet and new location. The new location is far west - outside of an easement that spans the property.} ; {Activity date: 08/24/2020; Status: Approved; Inspector: DROBERTS; Comment: Entered by RSALDAT1 - APPROVED AT THIS TIME. THE CONTRACTOR WILL POUR THE FOOTER ON 8/25/20.} ; {Activity date: 07/24/2020; Status: Continued; Inspector: HThrall; Comment: Entered by HTHRALL1 - INSPECTOR - REQUIRES FOOTER DEPTH / WIDTH INSPECTION FOR AN ENGINEERED SIGN + SETBACK + HEIGHT}
11/12/2021 COT - ENGR - Sign Electrical Passed {Activity date: 11/12/2021; Status: Approved; Inspector: DROBERTS; Comment: Entered by NGARCIA3 - APPROVED} ; {Activity date: 10/06/2020; Status: Continued; Inspector: HThrall; Comment: Entered by HTHRALL1 - Permit on HOLD - active sign violations at site - wall signs in violation of rezoning condition curfew of 7p. Electric for T20OT00143 (wall signs) and T20OT00215 locked due to active sign violations at site - including temporary / portable signs.

Sign contractor to contact Heather.Thrall@tucsonaz.gov or 520-837-4961 for further instruction.}

Documents

File Name Document Type  
T20OT00215_REVISED_LOCATION AND SIZE_MONUMENT_9191 E TANQUE VERDE_BRAKEMAX.PDF SIGNS VIEW
T20OT00215_REVISED_LOCATION PLAN_9191 E TANQUE VERDE_BRAKEMAX.PDF SIGNS VIEW
T20OT00215_APPD_APP_9191 E TANQUE VERDE_MONUMENT.PDF SIGNS VIEW
T20OT00215_APPD_PLANS_9191 E TANQUE VERDE_MONUMENT.PDF SIGNS VIEW
T20OT00215_APPD_MSP-20-004 DECISION_T20SA00138.PDF SIGNS VIEW
T20OT00215_SIGN PERMIT_9191 E TANQUE VERDE_MONUMENT.PDF SIGNS VIEW