Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T20CM08712
Permit Details
Apply Date:
12/12/2020
Applicant:
Lisa Bowers
Description:
Private Sewer for Bridges B-III
Permit Reviews
Permit Number - T20CM08712
Permit Status: Expired
Permit Description: Private Sewer for Bridges B-III
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
12/12/2020 | OTHER | 01/13/2021 | COMPLETED |
Outstanding Inspections
Permit Status: Expired
Permit Number: T20CM08712
Permite Description: Private Sewer for Bridges B-III
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/04/2022 | COT - LCPL - Plumbing Final | N/A | Canceled | Inspection Canceled |
11/07/2022 | PDSD Building Division Pre-Construction Meeting | N/A | Canceled | Inspection Canceled |
Completed Inspections
Permit Status: Expired
Permit Number: T20CM08712
Permit Description: Private Sewer for Bridges B-III
Total Completed Inspections - 1
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/24/2021 | COT - LCPL - Sewer | Passed | {Activity date: 03/24/2021; Status: Approved; Inspector: RCHANDLER; Comment: Entered by RSALDAT1 - PA. All except manholes and tests.} ; {Activity date: 03/22/2021; Status: Partial Approval; Inspector: TGAUSP; Comment: Entered by VLEON1 - Partially Approved, Manhole #3 NE approx 168’, okay to backfill, Also verified concrete base for Manhole #1} ; {Activity date: 03/19/2021; Status: Partial Approval; Inspector: TGAUSP; Comment: Entered by VLEON1 - Partial Approval-PA soil lines continued from Manhole #3 to Manhole #4 and 6” stub out 58’ due SE. okay to backfill} ; {Activity date: 03/18/2021; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by VLEON1 - PARTIAL 8 INCH SEWER LINE AND BRANH CONNECTIONS INSTALLED FROM MANHOLE 2-3} ; {Activity date: 03/17/2021; Status: Partial Approval; Inspector: TGAUSP; Comment: Entered by RSALDAT1 - Partial Approval-PA soil lines from Manhole #1 to Manhole #2, okay to backfill } ; {Activity date: 03/16/2021; Status: Not ready for Inspection; Inspector: TGAUSP; Comment: Entered by RSALDAT1 - - NR per contractor} ; {Activity date: 03/15/2021; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by VLEON1 - Partial, Interconnection between Public manhole and Private man hole ok to backfill.} |