Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Withdrwn
Type:
COMMERCIAL OTHER
Address:
2010 W ANKLAM RD
Apply Date:
11/02/2020
Applicant:
Scott Hopper
Description:
THIS PROJECT WILL BE COMPRISED OF: CHANGES ON THE EXISTING AT&T ANTENNA ARRAY: · REMOVE (1) EXISTING ANTENNA PER SECTOR, (3) SECTORS, (3) TOTAL · REMOVE (4) EXISTING LINES OF COAX PER SECTOR, (3) SECTORS, (12) TOTAL · REPLACE (1) EXISTING ANTENNA PER SECTOR, (3) SECTORS, (3) TOTAL · REMOVE (1) EXISTING TMA UNIT PER SECTOR , (3) SECTORS, (3) TOTAL · REPLACE (2) EXISTING RRH UNITS PER SECTOR, (3) SECTORS, (6) TOTAL CHANGES IN THE EXISTING AT&T EQUIPMENT ENCLOSURE AREA: · EXISTING ARGUS DC POWER PLANT TO BE REMOVED AND REPLACED · INSTALL (1) NEW VERTIV NETSURE 5100 POWER PLANT IN WUC · INSTALL (1) NEW 2-BAY WUC · INSTALL (1) NEW VERTIVE NETXEND BATTERY CABINET · REMOVE (2) EXISTING BATTERY CABINETS · REMOVE (1) EXISTING GSM · REMOVE (1) EXISTING AC PANEL · INSTALL (1) NEW 240/120, 200A 3-SOURCE PTLC ATS · REMOVE (1) EXISTING LTE CABINET · REMOVE (1) EXISTING MUX CABINET · REMOVE (1) EXISTING EXHAUST FAN AND ASSOCIATED DUCT WORK AC/DC SCOPE: DC POWER PLAN REVIEW: · EXISTING AC PANEL WILL BE REMOVED AS PART OF DECOMMISSIONING THE EXISTING DC POWER PLANT. INSTALL (1) NEW 240/120, 200A 3-SOURCE PTLC INTEGRATES 300-G ATS; STRIKESORB; 30-POS SQD NQ LOADCENTER [NEQ.20110]. · REMOVE EXISTING -48VDC TE41 POWER PLANT. INSTALL NEW NETSURE™ 5100 SERIES [NEQ.20193] OUTFITTED WITH (10) HE 2KW -48VDC RECTIFIERS [NEQ. 15930] & (4) HE 1.5KW -48VDC/+24VDC CONVERTER MODULES [NEQ. 15929]. · INSTALL THE FOLLOWING DC BREAKERS: (6) ESURE™ POWER EXTEND CONVERTERS, -58VDC, 1000W [NEQ.44717 ] AIRSCALE DUAL BAND B12/14 AHLBA (6) ESURE™ POWER EXTEND CONVERTERS, -58VDC, 1000W [NEQ.44717 ] AIRSCALE DUAL BAND B25/66 AHFIB (2) 20A [NEQ. 00466] NOKIA FSM4 BBU #1 & #2 (3) 150A [NEQ.00714] UMTS (2) 60A [NEQ. 00711] FUSE PANEL (1) 10A [NEQ. 00705] CIENA

Permit Reviews

Permit Number - T20CM07581
Permit Status: Withdrwn
Permit Description: THIS PROJECT WILL BE COMPRISED OF: CHANGES ON THE EXISTING AT&T ANTENNA ARRAY: · REMOVE (1) EXISTING ANTENNA PER SECTOR, (3) SECTORS, (3) TOTAL · REMOVE (4) EXISTING LINES OF COAX PER SECTOR, (3) SECTORS, (12) TOTAL · REPLACE (1) EXISTING ANTENNA PER SECTOR, (3) SECTORS, (3) TOTAL · REMOVE (1) EXISTING TMA UNIT PER SECTOR , (3) SECTORS, (3) TOTAL · REPLACE (2) EXISTING RRH UNITS PER SECTOR, (3) SECTORS, (6) TOTAL CHANGES IN THE EXISTING AT&T EQUIPMENT ENCLOSURE AREA: · EXISTING ARGUS DC POWER PLANT TO BE REMOVED AND REPLACED · INSTALL (1) NEW VERTIV NETSURE 5100 POWER PLANT IN WUC · INSTALL (1) NEW 2-BAY WUC · INSTALL (1) NEW VERTIVE NETXEND BATTERY CABINET · REMOVE (2) EXISTING BATTERY CABINETS · REMOVE (1) EXISTING GSM · REMOVE (1) EXISTING AC PANEL · INSTALL (1) NEW 240/120, 200A 3-SOURCE PTLC ATS · REMOVE (1) EXISTING LTE CABINET · REMOVE (1) EXISTING MUX CABINET · REMOVE (1) EXISTING EXHAUST FAN AND ASSOCIATED DUCT WORK AC/DC SCOPE: DC POWER PLAN REVIEW: · EXISTING AC PANEL WILL BE REMOVED AS PART OF DECOMMISSIONING THE EXISTING DC POWER PLANT. INSTALL (1) NEW 240/120, 200A 3-SOURCE PTLC INTEGRATES 300-G ATS; STRIKESORB; 30-POS SQD NQ LOADCENTER [NEQ.20110]. · REMOVE EXISTING -48VDC TE41 POWER PLANT. INSTALL NEW NETSURE™ 5100 SERIES [NEQ.20193] OUTFITTED WITH (10) HE 2KW -48VDC RECTIFIERS [NEQ. 15930] & (4) HE 1.5KW -48VDC/+24VDC CONVERTER MODULES [NEQ. 15929]. · INSTALL THE FOLLOWING DC BREAKERS: (6) ESURE™ POWER EXTEND CONVERTERS, -58VDC, 1000W [NEQ.44717 ] AIRSCALE DUAL BAND B12/14 AHLBA (6) ESURE™ POWER EXTEND CONVERTERS, -58VDC, 1000W [NEQ.44717 ] AIRSCALE DUAL BAND B25/66 AHFIB (2) 20A [NEQ. 00466] NOKIA FSM4 BBU #1 & #2 (3) 150A [NEQ.00714] UMTS (2) 60A [NEQ. 00711] FUSE PANEL (1) 10A [NEQ. 00705] CIENA
Start Date Submittal Complete Date Status  
11/05/2020 CELL TOWER/ANTENNAS 11/09/2020 ACTIVE Review Details