Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Address Search: 2010 W ANKLAM RD
Search
Parcel Attributes
Parcel | 11614163A 99999999C |
---|---|
Jurisdiction | Tucson |
City of Tucson Zoning | C-1 |
Water Course | Washes |
Tucson Ward | Ward 1 |
Tucson Registered Neighborhood | Santiago Hills |
Major Streets & Routes | Scenic Route |
Pima County Data | Assessor, Recorder, Treasurer, ... |
Parcel Map | Map |
Annexations & Original City Zoning (OCZ)
Address: 2010 W ANKLAM RD
Date - 11/23/2024 2:49 p.m.
Total Number Of Annexations & Original City Zoning (1)
Permits
Address: 2010 W ANKLAM RD
Date - 11/23/2024 2:49 p.m.
Total Number Of Permits - (36)
Permit | Status | Apply Date | Expired Date | Unit | Type | Description |
---|---|---|---|---|---|---|
TR-UTL-1222-00538 | Complete | 12/30/2022 | 05/21/2023 | Right-of-Way (ROW) - Utility | Cox to trench 46' and bore 302' to install CATV conduit for a service repair order | |
TC-UTL-0824-00059 | Issued | 08/07/2024 | 03/22/2025 | Utilities Permit | TOWER WORK: REMOVING: · REMOVE (3) EXISTING SECTOR FACE PIPE MOUNTS · REMOVE (6) EXISTING ANTENNAS · REMOVE (6) EXISTING RADIOS · REMOVE (3) TMAS INSTALLING: · INSTALL (3) PROPOSED 3.5" OD x 8' LONG FACE MOUNT PIPES · INSTALL (6) PROPOSED 2"Ø SCH 40 (2-3/8" O.D.) X 10' LONG MOUNT PIPES · INSTALL (12) PROPOSED ANTENNAS · INSTALL (9) PROPOSED RADIOS · INSTALL (1) PROPOSED SQUID · INSTALL (3) PROPOSED 6AWG DC TRUNKS · INSTALL (1) PROPOSED 24PR FIBER TRUNK · INSTALL (6) PROPOSED RR-FA2 DUAL RRU BRACKETS · INSTALL PROPOSED COAX HARGER BRACKETS | |
TC-UTL-0724-00054 | Void | 07/29/2024 | N/A | Utilities Permit | **VOID: YL - Duplicate/Same scope of work as existing application permit TC-UTL-0423-00063. Please resubmit under existing permit or withdraw existing permit before moving forward with a new application. Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf For questions: Building_Official@tucsonaz.gov ** -Remove existing antennas, radios & TMAs Install new antennas, radios, squid and trunks | |
T22CM03258 | Issued | 04/29/2022 | 07/19/2023 | Commercial Building | Modification to an Existing Monopalm by adding (3) antennas, (6) radio heads, (1) Raycap, (1) hybrid | |
TC-UTL-0423-00063 | Withdrawn | 04/28/2023 | N/A | Utilities Permit | Changes to Existing Monopalm that includes replacing existing antennas and surge suppressors ($40,000.00) CHANGES ON THE EXISTING MONOPALM: · POSITION 3- REMOVE (1) ANTENNA PER SECTOR, (3) SECTOR, (3) TOTAL · POSITION 3- INSTALL (2) STACKED ANTENNA/RRH, PER SECTOR, (3) SECTOR, (6) TOTAL · INSTALL (1) DC9 SURGE SUPPRESSOR TOTAL · INSTALL (3) 6AWG DC TRUNK & (1) 24-PAIR FIBER TRUNK CHANGES IN THE EXISTING AT&T EQUIPMENT ENCLOSURE AREA: AC/DC SCOPE: DC POWER PLAN REVIEW: · SITE HAS AN EXISTING EMERSON 5100 -48VDC POWER PLANT OUTFITTED WITH (10) HE 2KW -48VDC RECTIFIERS [NEQ. 15930] & (0) HE 1.5KW -48VDC/+24VDC CONVERTER MODULES [NEQ.15929]. EXISTING RECTIFIERS ARE SUFFICIENT, NO CHANGES ARE NECESSARY TO THE EXISTING DC POWER PLANT. · DC BREAKERS: INSTALL THE FOLLOWING DC BREAKERS: · (3) 40A [NEQ. 00185] FOR NEW AEQK ANTENNAS · (3) 40A [NEQ. 00185] FOR NEW AEQU ANTENNAS BATTERY CHECK: · NO PERMANENT STANDBY GENERATOR, MINIMUM REQUIRED BATTERY BACKUP TIME IS 4.0 HOURS · SITE HAS (16) CELLS OF EXISTING MARATHON M12V180FT BATTERIES, WHICH ARE SUFFICIENT. FOUR BATTERY STRINGS WILL PROVIDE 4.12 HRS OF BATTERY RESERVE CAPACITY. A/C PANEL REVIEW: · SEE PANEL SCHEDULE · NO CHANGES ARE NECESSARY TO THE EXISTING AC POWER PANEL. EXISTING 200A ELECTRICAL SERVICE IS SUFFICIENT. HVAC UNITS: · WUC SITE, FACTORY-INSTALLED DC HEAT EXCHANGERS. | |
DP22-0292 | CLOSED | 10/20/2022 | N/A | DEVPKG | · POSITION 3- REMOVE (1) ANTENNA PER SECTOR, (3) SECTOR, (3) TOTAL · POSITION 3- INSTALL (2) STACKED ANTENNA/RRH, PER SECTOR, (3) SECTOR, (6) TOTAL · INSTALL (1) DC9 SURGE SUPPRESSOR TOTAL · INSTALL (3) 6AWG DC TRUNK & (1) 24-PAIR FIBER TRUNK | |
P99AN01328 | ISSUED | 05/13/1999 | N/A | ADDRNEW | ||
P99AN02241 | ISSUED | 08/09/1999 | N/A | #100 | ADDRNEW | |
T00BU00854 | FINAL | 03/22/2000 | 12/25/2000 | SPKLR | FIRE SPKR:PIPING 80 4" | |
T00BU00855 | FINAL | 03/22/2000 | 12/25/2000 | SPKLR | FIRE SPKR:70 NEW | |
T00BU03551 | EXPIRED | 12/05/2000 | 12/11/2001 | BUILD | ADDITION:CARPORT | |
T00EX00592 | CLOSED | 04/19/2000 | 06/18/2000 | EXCAV | EXCAV:200 LF | |
T00EX00746 | CLOSED | 05/19/2000 | 07/18/2000 | EXCAV | EXCAV:60LF IN PAVEMENT | |
T02BU01797 | FINAL | 06/21/2002 | 02/16/2003 | #150 | SPKLR | FIRE SPKR:RELOCATE 13 & ADD 8 |
T02CM01092 | C OF O | 02/26/2002 | 02/18/2003 | COMBO | TI:OFFICE | |
T02OT01971 | EXPIRED | 12/18/2002 | 09/14/2003 | SIGN | SIGN:4875 | |
T06OT02588 | EXPIRED | 10/06/2006 | 04/09/2007 | #150 | SIGN | 11954 |
T09CM01949 | FINAL | 07/21/2009 | 11/28/2010 | COMBO | LOCATE OUTDOOR EQUIPMENT CABINETS, ENCLOSE CELLULAR EQUIPMENT, TOWER INSTALLATION | |
T11EX00443 | CLOSED | 08/18/2011 | 10/17/2011 | EXCAV | PVC OR CONDUIT | |
T12CM02775 | EXPIRED | 05/17/2012 | 05/07/2014 | #100 | COMBO | REMOVE/INSTALL ANTENNAS AND ASSOCIATED EQUIPMENT ON EXISTING WIRELESS COMM FACILITY AND WITHIN THE EXISTING GROUND EQUIPMENT COMPOUND |
T12CM06283 | EXPIRED | 10/08/2012 | 04/06/2013 | COMBO | TEMP MOBILE FACILITY "CELL-ON-WHEELS" | |
T12CM07621 | FINAL | 12/03/2012 | 06/03/2013 | #150 | COMBO | RECONNECT ELECTRIC; COMM |
T12TUP0020 | CLOSED | 09/20/2012 | 12/03/2012 | TUP | CELL ON WHEELS IS NEEDED TO MAINTAIN AT&T WIRELESS SERVICE IN THE AREA | |
T13CM06981 | FINAL | 11/15/2013 | 06/24/2014 | #100 | COMBO | SOLAR PV |
T14TC03091 | CLOSED | 12/08/2014 | N/A | BARRICAD | Tucson Water Maintenance Daily 11-26-14 | |
T16CM05306 | FINAL | 07/08/2016 | 08/06/2017 | COMBO | CELLL TOWER UPGRADE | |
T16EX01387 | EXPIRED | 04/19/2016 | 07/15/2016 | EXCAV | BORE ACROSS ANKLAM RD FROM OUR EXISTING MH AND REPLACE 1 PEDESTAL IN THE ALLEY. ACCESS MANHOLE # 15235 FOR SPLICING. WORK ORDER # N.054190 This project is located in an Archaeological Sensitivity Zone. An Archaeological Monitor hired by the permit applicant is required to be on-site during any digging, unless a waiver is issued. Monitoring reports are to be submitted to Jonathan Mabry, Historic Preservation Office, City of Tucson, P.O. Box 27210, Tucson, AZ 85726.** Contact Jonathan Mabry at 520-837-6968 or jonathan.mabry@tucsonaz.gov with any questions. | |
T16TC00966 | EXPIRED | 04/19/2016 | N/A | BARRICAD | BORE ACROSS ANKLAM RD FROM OUR EXISTING MH AND REPLACE 1 PEDESTAL IN THE ALLEY. ACCESS MANHOLE # 15235 FOR SPLICING. 06/27/2016-PLAN CHANGE R1 WORK ORDER # N.054190 | |
T16TC01003 | EXPIRED | 04/22/2016 | N/A | BARRICAD | ACCESSING 9 MANHOLES TO PULL FIBER, STARTS AT BONITA & CONGRESS AND ENDS PAST FRESNO & WESTMORELAND WORK ORDER # N.054190-1 | |
T16TC01004 | VOID | 04/22/2016 | N/A | BARRICAD | ACCESSING 9 MANHOLES TO PULL FIBER, STARTS AT BONITA & CONGRESS AND ENDS PAST FRESNO & WESTMORELAND WORK ORDER # N.054190-1 | |
T16TC01005 | EXPIRED | 04/22/2016 | N/A | BARRICAD | ACCESSING 98 MANHOLES TO PULL FIBERT, STARTS AT SILVERBELL AND ENDS ON ANKLAM WORK ORDER # N.054190-2 | |
T20CM07510 | FINAL | 10/29/2020 | 12/08/2021 | COMBO | CELL TOWER MODIFICATION (AT&T) | |
T20CM07581 | WITHDRWN | 11/02/2020 | N/A | COMBO | THIS PROJECT WILL BE COMPRISED OF: CHANGES ON THE EXISTING AT&T ANTENNA ARRAY: · REMOVE (1) EXISTING ANTENNA PER SECTOR, (3) SECTORS, (3) TOTAL · REMOVE (4) EXISTING LINES OF COAX PER SECTOR, (3) SECTORS, (12) TOTAL · REPLACE (1) EXISTING ANTENNA PER SECTOR, (3) SECTORS, (3) TOTAL · REMOVE (1) EXISTING TMA UNIT PER SECTOR , (3) SECTORS, (3) TOTAL · REPLACE (2) EXISTING RRH UNITS PER SECTOR, (3) SECTORS, (6) TOTAL CHANGES IN THE EXISTING AT&T EQUIPMENT ENCLOSURE AREA: · EXISTING ARGUS DC POWER PLANT TO BE REMOVED AND REPLACED · INSTALL (1) NEW VERTIV NETSURE 5100 POWER PLANT IN WUC · INSTALL (1) NEW 2-BAY WUC · INSTALL (1) NEW VERTIVE NETXEND BATTERY CABINET · REMOVE (2) EXISTING BATTERY CABINETS · REMOVE (1) EXISTING GSM · REMOVE (1) EXISTING AC PANEL · INSTALL (1) NEW 240/120, 200A 3-SOURCE PTLC ATS · REMOVE (1) EXISTING LTE CABINET · REMOVE (1) EXISTING MUX CABINET · REMOVE (1) EXISTING EXHAUST FAN AND ASSOCIATED DUCT WORK AC/DC SCOPE: DC POWER PLAN REVIEW: · EXISTING AC PANEL WILL BE REMOVED AS PART OF DECOMMISSIONING THE EXISTING DC POWER PLANT. INSTALL (1) NEW 240/120, 200A 3-SOURCE PTLC INTEGRATES 300-G ATS; STRIKESORB; 30-POS SQD NQ LOADCENTER [NEQ.20110]. · REMOVE EXISTING -48VDC TE41 POWER PLANT. INSTALL NEW NETSURE™ 5100 SERIES [NEQ.20193] OUTFITTED WITH (10) HE 2KW -48VDC RECTIFIERS [NEQ. 15930] & (4) HE 1.5KW -48VDC/+24VDC CONVERTER MODULES [NEQ. 15929]. · INSTALL THE FOLLOWING DC BREAKERS: (6) ESURE™ POWER EXTEND CONVERTERS, -58VDC, 1000W [NEQ.44717 ] AIRSCALE DUAL BAND B12/14 AHLBA (6) ESURE™ POWER EXTEND CONVERTERS, -58VDC, 1000W [NEQ.44717 ] AIRSCALE DUAL BAND B25/66 AHFIB (2) 20A [NEQ. 00466] NOKIA FSM4 BBU #1 & #2 (3) 150A [NEQ.00714] UMTS (2) 60A [NEQ. 00711] FUSE PANEL (1) 10A [NEQ. 00705] CIENA | |
T99BU02357 | FINAL | 08/27/1999 | 08/11/2007 | GRADING | GRADING:CUT 1600 FILL 300 | |
T99CM02302 | C OF O | 05/13/1999 | 12/20/2000 | #100 | COMBO | OFFICE BUILDING |
T99CM04856 | EXPIRED | 10/13/1999 | 01/03/2001 | #150 | COMBO | OFFICE |
Plans
Address: 2010 W ANKLAM RD
Date - 11/23/2024 2:49 p.m.
Total Number Of Plans - (2)
Plan Number | Status | Application Date | Exp Date | Unit | Type | Description |
---|---|---|---|---|---|---|
T08SE00002 | Effectuated | 02/11/2008 | 02/11/2009 | -- Zoning Examiner Special Exception | SE-08-02 AT&T-Anklam Rd - The preliminary development plan dated 2/8/08 proposes a new wireless communication facility comprised of a 55' high stealth designed monopalm with associated ground equipment on a 450 sqft lease area. | |
T07PRE0066 | APPLIED | 08/30/2007 | N/A | NEIGHBORHOOD NOTIFICATION -- LABELS | Prposed AT&T telecommunication facility - monopalm, 55 feet in height, within an enclosure, 10 X 30 feet in size. |
Record Requests
Address: 2010 W ANKLAM RD
Date - 11/23/2024 2:49 p.m.
Total Number Of Requests - (1)
Request Number | Status | Request Date | Completed Date | Type | Description |
---|---|---|---|---|---|
REQ-0824-05350 | Complete | 08/07/2024 | 08/07/2024 | Requests | Changes to Existing Monopalm that includes replacing existing antennas and surge suppressors ($40,000.00) CHANGES ON THE EXISTING MONOPALM: · POSITION 3- REMOVE (1) ANTENNA PER SECTOR, (3) SECTOR, (3) TOTAL · POSITION 3- INSTALL (2) STACKED ANTENNA/RRH, PER SECTOR, (3) SECTOR, (6) TOTAL · INSTALL (1) DC9 SURGE SUPPRESSOR TOTAL · INSTALL (3) 6AWG DC TRUNK & (1) 24-PAIR FIBER TRUNK CHANGES IN THE EXISTING AT&T EQUIPMENT ENCLOSURE AREA: AC/DC SCOPE: DC POWER PLAN REVIEW: · SITE HAS AN EXISTING EMERSON 5100 -48VDC POWER PLANT OUTFITTED WITH (10) HE 2KW -48VDC RECTIFIERS [NEQ. 15930] & (0) HE 1.5KW -48VDC/+24VDC CONVERTER MODULES [NEQ.15929]. EXISTING RECTIFIERS ARE SUFFICIENT, NO CHANGES ARE NECESSARY TO THE EXISTING DC POWER PLANT. · DC BREAKERS: INSTALL THE FOLLOWING DC BREAKERS: · (3) 40A [NEQ. 00185] FOR NEW AEQK ANTENNAS · (3) 40A [NEQ. 00185] FOR NEW AEQU ANTENNAS BATTERY CHECK: · NO PERMANENT STANDBY GENERATOR, MINIMUM REQUIRED BATTERY BACKUP TIME IS 4.0 HOURS · SITE HAS (16) CELLS OF EXISTING MARATHON M12V180FT BATTERIES, WHICH ARE SUFFICIENT. FOUR BATTERY STRINGS WILL PROVIDE 4.12 HRS OF BATTERY RESERVE CAPACITY. A/C PANEL REVIEW: · SEE PANEL SCHEDULE · NO CHANGES ARE NECESSARY TO THE EXISTING AC POWER PANEL. EXISTING 200A ELECTRICAL SERVICE IS SUFFICIENT. HVAC UNITS: · WUC SITE, FACTORY-INSTALLED DC HEAT EXCHANGERS. |