Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Search

Parcel Attributes

Parcel11614163A
JurisdictionTucson, Pima County
Water Course

Wash

City of Tucson ZoningC-1
Tucson WardWard 1
Tucson Registered NeighborhoodSantiago Hills
Major Street & Route

Scenic Route

Pima County Data Assessor, Recorder, Treasurer, ...
Parcel Map Map
Parcel Attributes Issue?

Annexations & Original City Zoning (OCZ)

Address: 2010 W ANKLAM RD
Date - 09/05/2026 6:17 p.m.
Total Number Of Annexations & Original City Zoning (1)
Plan Description Annexation Ordinance Effective Date OCZ Ordinance
C9-60-39 West To Silverbell Road And South To San Xavier Indian Reservation 2014 2045

Permits

Address: 2010 W ANKLAM RD
Date - 09/05/2026 6:17 p.m.
Total Number Of Permits - (36)
Permit Status Apply Date Expired Date Unit Type Description
TR-UTL-1222-00538 Complete 12/30/2022 05/21/2023 Right-of-Way (ROW) - Utility Cox to trench 46' and bore 302' to install CATV conduit for a service repair order
TC-UTL-0824-00059 Issued 08/07/2024 03/22/2025 Utilities Permit TOWER WORK: REMOVING: · REMOVE (3) EXISTING SECTOR FACE PIPE MOUNTS · REMOVE (6) EXISTING ANTENNAS · REMOVE (6) EXISTING RADIOS · REMOVE (3) TMAS INSTALLING: · INSTALL (3) PROPOSED 3.5" OD x 8' LONG FACE MOUNT PIPES · INSTALL (6) PROPOSED 2"Ø SCH 40 (2-3/8" O.D.) X 10' LONG MOUNT PIPES · INSTALL (12) PROPOSED ANTENNAS · INSTALL (9) PROPOSED RADIOS · INSTALL (1) PROPOSED SQUID · INSTALL (3) PROPOSED 6AWG DC TRUNKS · INSTALL (1) PROPOSED 24PR FIBER TRUNK · INSTALL (6) PROPOSED RR-FA2 DUAL RRU BRACKETS · INSTALL PROPOSED COAX HARGER BRACKETS
TC-UTL-0724-00054 Void 07/29/2024 N/A Utilities Permit **VOID: YL - Duplicate/Same scope of work as existing application permit TC-UTL-0423-00063. Please resubmit under existing permit or withdraw existing permit before moving forward with a new application. Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf For questions: Building_Official@tucsonaz.gov ** -Remove existing antennas, radios & TMAs Install new antennas, radios, squid and trunks
T22CM03258 Issued 04/29/2022 07/19/2023 Commercial Building Modification to an Existing Monopalm by adding (3) antennas, (6) radio heads, (1) Raycap, (1) hybrid
TC-UTL-0423-00063 Withdrawn 04/28/2023 N/A Utilities Permit Changes to Existing Monopalm that includes replacing existing antennas and surge suppressors ($40,000.00) CHANGES ON THE EXISTING MONOPALM: · POSITION 3- REMOVE (1) ANTENNA PER SECTOR, (3) SECTOR, (3) TOTAL · POSITION 3- INSTALL (2) STACKED ANTENNA/RRH, PER SECTOR, (3) SECTOR, (6) TOTAL · INSTALL (1) DC9 SURGE SUPPRESSOR TOTAL · INSTALL (3) 6AWG DC TRUNK & (1) 24-PAIR FIBER TRUNK CHANGES IN THE EXISTING AT&T EQUIPMENT ENCLOSURE AREA: AC/DC SCOPE: DC POWER PLAN REVIEW: · SITE HAS AN EXISTING EMERSON 5100 -48VDC POWER PLANT OUTFITTED WITH (10) HE 2KW -48VDC RECTIFIERS [NEQ. 15930] & (0) HE 1.5KW -48VDC/+24VDC CONVERTER MODULES [NEQ.15929]. EXISTING RECTIFIERS ARE SUFFICIENT, NO CHANGES ARE NECESSARY TO THE EXISTING DC POWER PLANT. · DC BREAKERS: INSTALL THE FOLLOWING DC BREAKERS: · (3) 40A [NEQ. 00185] FOR NEW AEQK ANTENNAS · (3) 40A [NEQ. 00185] FOR NEW AEQU ANTENNAS BATTERY CHECK: · NO PERMANENT STANDBY GENERATOR, MINIMUM REQUIRED BATTERY BACKUP TIME IS 4.0 HOURS · SITE HAS (16) CELLS OF EXISTING MARATHON M12V180FT BATTERIES, WHICH ARE SUFFICIENT. FOUR BATTERY STRINGS WILL PROVIDE 4.12 HRS OF BATTERY RESERVE CAPACITY. A/C PANEL REVIEW: · SEE PANEL SCHEDULE · NO CHANGES ARE NECESSARY TO THE EXISTING AC POWER PANEL. EXISTING 200A ELECTRICAL SERVICE IS SUFFICIENT. HVAC UNITS: · WUC SITE, FACTORY-INSTALLED DC HEAT EXCHANGERS.
DP22-0292 CLOSED 10/20/2022 N/A DEVPKG · POSITION 3- REMOVE (1) ANTENNA PER SECTOR, (3) SECTOR, (3) TOTAL · POSITION 3- INSTALL (2) STACKED ANTENNA/RRH, PER SECTOR, (3) SECTOR, (6) TOTAL · INSTALL (1) DC9 SURGE SUPPRESSOR TOTAL · INSTALL (3) 6AWG DC TRUNK & (1) 24-PAIR FIBER TRUNK
P99AN01328 ISSUED 05/13/1999 N/A ADDRNEW
P99AN02241 ISSUED 08/09/1999 N/A #100 ADDRNEW
T00BU00854 FINAL 03/22/2000 12/25/2000 SPKLR FIRE SPKR:PIPING 80 4"
T00BU00855 FINAL 03/22/2000 12/25/2000 SPKLR FIRE SPKR:70 NEW
T00BU03551 EXPIRED 12/05/2000 12/11/2001 BUILD ADDITION:CARPORT
T00EX00592 CLOSED 04/19/2000 06/18/2000 EXCAV EXCAV:200 LF
T00EX00746 CLOSED 05/19/2000 07/18/2000 EXCAV EXCAV:60LF IN PAVEMENT
T02BU01797 FINAL 06/21/2002 02/16/2003 #150 SPKLR FIRE SPKR:RELOCATE 13 & ADD 8
T02CM01092 C OF O 02/26/2002 02/18/2003 COMBO TI:OFFICE
T02OT01971 EXPIRED 12/18/2002 09/14/2003 SIGN SIGN:4875
T06OT02588 EXPIRED 10/06/2006 04/09/2007 #150 SIGN 11954
T09CM01949 FINAL 07/21/2009 11/28/2010 COMBO LOCATE OUTDOOR EQUIPMENT CABINETS, ENCLOSE CELLULAR EQUIPMENT, TOWER INSTALLATION
T11EX00443 CLOSED 08/18/2011 10/17/2011 EXCAV PVC OR CONDUIT
T12CM02775 EXPIRED 05/17/2012 05/07/2014 #100 COMBO REMOVE/INSTALL ANTENNAS AND ASSOCIATED EQUIPMENT ON EXISTING WIRELESS COMM FACILITY AND WITHIN THE EXISTING GROUND EQUIPMENT COMPOUND
T12CM06283 EXPIRED 10/08/2012 04/06/2013 COMBO TEMP MOBILE FACILITY "CELL-ON-WHEELS"
T12CM07621 FINAL 12/03/2012 06/03/2013 #150 COMBO RECONNECT ELECTRIC; COMM
T12TUP0020 CLOSED 09/20/2012 12/03/2012 TUP CELL ON WHEELS IS NEEDED TO MAINTAIN AT&T WIRELESS SERVICE IN THE AREA
T13CM06981 FINAL 11/15/2013 06/24/2014 #100 COMBO SOLAR PV
T14TC03091 CLOSED 12/08/2014 N/A BARRICAD Tucson Water Maintenance Daily 11-26-14
T16CM05306 FINAL 07/08/2016 08/06/2017 COMBO CELLL TOWER UPGRADE
T16EX01387 EXPIRED 04/19/2016 07/15/2016 EXCAV BORE ACROSS ANKLAM RD FROM OUR EXISTING MH AND REPLACE 1 PEDESTAL IN THE ALLEY. ACCESS MANHOLE # 15235 FOR SPLICING. WORK ORDER # N.054190 This project is located in an Archaeological Sensitivity Zone. An Archaeological Monitor hired by the permit applicant is required to be on-site during any digging, unless a waiver is issued. Monitoring reports are to be submitted to Jonathan Mabry, Historic Preservation Office, City of Tucson, P.O. Box 27210, Tucson, AZ 85726.** Contact Jonathan Mabry at 520-837-6968 or jonathan.mabry@tucsonaz.gov with any questions.
T16TC00966 EXPIRED 04/19/2016 N/A BARRICAD BORE ACROSS ANKLAM RD FROM OUR EXISTING MH AND REPLACE 1 PEDESTAL IN THE ALLEY. ACCESS MANHOLE # 15235 FOR SPLICING. 06/27/2016-PLAN CHANGE R1 WORK ORDER # N.054190
T16TC01003 EXPIRED 04/22/2016 N/A BARRICAD ACCESSING 9 MANHOLES TO PULL FIBER, STARTS AT BONITA & CONGRESS AND ENDS PAST FRESNO & WESTMORELAND WORK ORDER # N.054190-1
T16TC01004 VOID 04/22/2016 N/A BARRICAD ACCESSING 9 MANHOLES TO PULL FIBER, STARTS AT BONITA & CONGRESS AND ENDS PAST FRESNO & WESTMORELAND WORK ORDER # N.054190-1
T16TC01005 EXPIRED 04/22/2016 N/A BARRICAD ACCESSING 98 MANHOLES TO PULL FIBERT, STARTS AT SILVERBELL AND ENDS ON ANKLAM WORK ORDER # N.054190-2
T20CM07510 FINAL 10/29/2020 12/08/2021 COMBO CELL TOWER MODIFICATION (AT&T)
T20CM07581 WITHDRWN 11/02/2020 N/A COMBO THIS PROJECT WILL BE COMPRISED OF: CHANGES ON THE EXISTING AT&T ANTENNA ARRAY: · REMOVE (1) EXISTING ANTENNA PER SECTOR, (3) SECTORS, (3) TOTAL · REMOVE (4) EXISTING LINES OF COAX PER SECTOR, (3) SECTORS, (12) TOTAL · REPLACE (1) EXISTING ANTENNA PER SECTOR, (3) SECTORS, (3) TOTAL · REMOVE (1) EXISTING TMA UNIT PER SECTOR , (3) SECTORS, (3) TOTAL · REPLACE (2) EXISTING RRH UNITS PER SECTOR, (3) SECTORS, (6) TOTAL CHANGES IN THE EXISTING AT&T EQUIPMENT ENCLOSURE AREA: · EXISTING ARGUS DC POWER PLANT TO BE REMOVED AND REPLACED · INSTALL (1) NEW VERTIV NETSURE 5100 POWER PLANT IN WUC · INSTALL (1) NEW 2-BAY WUC · INSTALL (1) NEW VERTIVE NETXEND BATTERY CABINET · REMOVE (2) EXISTING BATTERY CABINETS · REMOVE (1) EXISTING GSM · REMOVE (1) EXISTING AC PANEL · INSTALL (1) NEW 240/120, 200A 3-SOURCE PTLC ATS · REMOVE (1) EXISTING LTE CABINET · REMOVE (1) EXISTING MUX CABINET · REMOVE (1) EXISTING EXHAUST FAN AND ASSOCIATED DUCT WORK AC/DC SCOPE: DC POWER PLAN REVIEW: · EXISTING AC PANEL WILL BE REMOVED AS PART OF DECOMMISSIONING THE EXISTING DC POWER PLANT. INSTALL (1) NEW 240/120, 200A 3-SOURCE PTLC INTEGRATES 300-G ATS; STRIKESORB; 30-POS SQD NQ LOADCENTER [NEQ.20110]. · REMOVE EXISTING -48VDC TE41 POWER PLANT. INSTALL NEW NETSURE™ 5100 SERIES [NEQ.20193] OUTFITTED WITH (10) HE 2KW -48VDC RECTIFIERS [NEQ. 15930] & (4) HE 1.5KW -48VDC/+24VDC CONVERTER MODULES [NEQ. 15929]. · INSTALL THE FOLLOWING DC BREAKERS: (6) ESURE™ POWER EXTEND CONVERTERS, -58VDC, 1000W [NEQ.44717 ] AIRSCALE DUAL BAND B12/14 AHLBA (6) ESURE™ POWER EXTEND CONVERTERS, -58VDC, 1000W [NEQ.44717 ] AIRSCALE DUAL BAND B25/66 AHFIB (2) 20A [NEQ. 00466] NOKIA FSM4 BBU #1 & #2 (3) 150A [NEQ.00714] UMTS (2) 60A [NEQ. 00711] FUSE PANEL (1) 10A [NEQ. 00705] CIENA
T99BU02357 FINAL 08/27/1999 08/11/2007 GRADING GRADING:CUT 1600 FILL 300
T99CM02302 C OF O 05/13/1999 12/20/2000 #100 COMBO OFFICE BUILDING
T99CM04856 EXPIRED 10/13/1999 01/03/2001 #150 COMBO OFFICE

Plans

Address: 2010 W ANKLAM RD
Date - 09/05/2026 6:17 p.m.
Total Number Of Plans - (2)
Plan Number Status Application Date Exp Date Unit Type Description
T08SE00002 Effectuated 02/11/2008 02/11/2009 -- Zoning Examiner Special Exception SE-08-02 AT&T-Anklam Rd - The preliminary development plan dated 2/8/08 proposes a new wireless communication facility comprised of a 55' high stealth designed monopalm with associated ground equipment on a 450 sqft lease area.
T07PRE0066 APPLIED 08/30/2007 N/A NEIGHBORHOOD NOTIFICATION -- LABELS Prposed AT&T telecommunication facility - monopalm, 55 feet in height, within an enclosure, 10 X 30 feet in size.