Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T20CM02633
Permit Details
Apply Date:
04/28/2020
Applicant:
Description:
ADD: SHOP, CARPORT & MASTER SUITE
Permit Reviews
Permit Number - T20CM02633
Permit Status: Complete
Permit Description: ADD: SHOP, CARPORT & MASTER SUITE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/28/2020 | RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO | 08/24/2020 | COMPLETED |
05/19/2020 | OTHER | 08/24/2020 | COMPLETED |
08/24/2020 | RESUBMITTAL | 10/28/2020 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T20CM02633
Permit Status: Complete
Permit Description: ADD: SHOP, CARPORT & MASTER SUITE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
04/28/2020 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Conditions
Permit Number - T20CM02633
Permit Status: Complete
Permit Description: ADD: SHOP, CARPORT & MASTER SUITE
Date | Description | Comments |
---|---|---|
10/26/2020 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
Outstanding Inspections
Permit Status: Complete
Permit Number: T20CM02633
Permite Description: ADD: SHOP, CARPORT & MASTER SUITE
Total Outstanding Inspections - 4
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/27/2022 | COT - RSEL - Electrical Final | N/A | Not Ready | |
10/27/2022 | RSBU - Building Final | N/A | Not Ready | |
10/27/2022 | COT - RSPL - Plumbing Final | N/A | Not Ready | |
10/27/2022 | COT - RSEL - Outdoor Lighting | N/A | Not Ready |
Completed Inspections
Permit Status: Complete
Permit Number: T20CM02633
Permit Description: ADD: SHOP, CARPORT & MASTER SUITE
Total Completed Inspections - 15
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/02/2021 | COT - RSBU - Stem Wall/Retaining Wall | Passed | {Activity date: 11/02/2021; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - AP} | |
11/12/2021 | COT - RSPL - Rough Soil | Passed | {Activity date: 11/12/2021; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved} | |
12/08/2021 | COT - RSBU - Preslab | Passed | {Activity date: 12/08/2021; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VVERA1 - AP} | |
12/08/2021 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 12/08/2021; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VVERA1 - AP} ; {Activity date: 10/19/2021; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - . Partial. 60 foot footing for east side garage wall.} | |
02/07/2022 | COT - RSBU - Roof Nailing | Passed | {Activity date: 02/07/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VVERA1 - AP} ; {Activity date: 02/03/2022; Status: Cancelled; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CA} ; {Activity date: 10/26/2020; Status: Prior to Intermediates; Inspector: KEN; Comment: Entered by KKARSEN1 - ROOF TRUSSES MUST BE APPROVED PRIOR TO INSPECTION} | |
02/07/2022 | COT - RSBU - Exterior Clips/Sheathing | Passed | {Activity date: 02/07/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VVERA1 - AP Note: Welding can be submitted before Final and bolting can be viewed at intermediate. Balance of corrections areOk by inspection. } |
|
04/13/2022 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 04/13/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - APPROVED} | |
04/13/2022 | RSME - Mechanical Progress | Passed | {Activity date: 04/13/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved} | |
04/18/2022 | COT - LCBU - Framing | Passed | {Activity date: 04/18/2022; Status: Approved; Inspector: KEN; Comment: Entered by KKARSEN1 - TRUSS PLANS FILED} ; {Activity date: 04/13/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - PARTIAL APPROVAL NEED APPROVED TRUSS CALCS} ; {Activity date: 02/03/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CO 1. Incorrect trimmers at north bedroom opening 2. Incorrect posting at 3-ply girder 3. Install thru-bolts in pocket per detail 4. Provide 3rd party inspection report on welds 5. Provide sealed truss calcs} |
|
07/25/2022 | COT - RSME - Mechanical Final | Passed | {Activity date: 07/25/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
07/25/2022 | COT - RSPL - Yard Water Line | Passed | {Activity date: 07/25/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
11/30/2022 | COT - RSEL - Electrical Final | Passed | ||
11/30/2022 | RSBU - Building Final | Passed | ||
11/30/2022 | COT - RSPL - Plumbing Final | Passed | ||
11/30/2022 | COT - RSEL - Outdoor Lighting | Passed |