Permit: T20CM01163
Permit Details
Apply Date:
02/20/2020
Applicant:
Description:
W - PRIVATE SEWER
Permit Reviews
Permit Number - T20CM01163
Permit Status: Expired
Permit Description: W - PRIVATE SEWER
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/20/2020 | OTHER | 04/15/2020 | COMPLETED |
| 04/15/2020 | RESUBMITTAL | 05/04/2020 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T20CM01163
Permit Status: Expired
Permit Description: W - PRIVATE SEWER
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 02/20/2020 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T20CM01163
Permite Description: W - PRIVATE SEWER
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/07/2022 | COT - LCPL - Plumbing Final | N/A | Canceled | Inspection Canceled |
Completed Inspections
Permit Status: Expired
Permit Number: T20CM01163
Permit Description: W - PRIVATE SEWER
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/07/2020 | PDSD Building Division Pre-Construction Meeting | Passed | {Activity date: 08/07/2020; Status: Approved; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Approved} | |
| 08/07/2020 | COT - LCPL - Sewer | Passed | {Activity date: 08/07/2020; Status: Approved; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Approved, All private Sewer lines air tested and mandriled from Each manhole to Public sewer.} ; {Activity date: 05/19/2020; Status: Partial Approval; Inspector: TVALENCIA; Comment: Entered by RSALDAT1 - partial 1- Site sewer is okay to cover. 2- Manholes 4,5 & 6 are okay to stack. 3- Shall provide an air test of 5 psi minimum at later date.} ; {Activity date: 05/14/2020; Status: Partial Approval; Inspector: TVALENCIA; Comment: Entered by RSALDAT1 - partial 1- 6 inch main site sewer line from Manhole 2 upstream to MH 3,4,5,6 and up to the 90 degree change of direction at the Building only. Okay to backfill at your own risk. Air test will be provided at a later date. 2- Manholes 2 & 3 okay to stack.} ; {Activity date: 05/06/2020; Status: Partial Approval; Inspector: TVALENCIA; Comment: Entered by RSALDAT1 - 1- Site Sewer from Manhole 2 to Manhole 3 okay to cover. Air pressure test to be provided at a later date. Okay to cover at own risk.} ; {Activity date: 05/05/2020; Status: Not ready for Inspection; Inspector: TVALENCIA; Comment: Entered by RSALDAT1 - 1- Contractor cancelled the inspection request. } ; {Activity date: 05/01/2020; Status: Partial Approval; Inspector: TVALENCIA; Comment: Entered by RSALDAT1 - 1- Site sewer between Man Hole 1 and Man Hole 2 is okay to cover at own risk. Air test to be provided at a later date. } ; {Activity date: 04/29/2020; Status: Partial Approval; Inspector: TVALENCIA; Comment: Entered by RSALDAT1 - 1- Site Sewer From Man Hole number 1, 20 feet upstream piping okay to cover.} |