Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
Residential Building - One or Two Family
Apply Date:
10/08/2019
Applicant:
Description:
E - INSTALL ROOFTOP SOLAR SYSTEM

Permit Reviews

Permit Number - T19CM07358
Permit Status: Expired
Permit Description: E - INSTALL ROOFTOP SOLAR SYSTEM
Start Date Submittal Complete Date Status  
10/08/2019 RESIDENTIAL - BLDG/ZONING-WALKTHRU 10/15/2019 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T19CM07358
Permit Status: Expired
Permit Description: E - INSTALL ROOFTOP SOLAR SYSTEM
Total Outstanding Activity Conditions - 2
Date Name
10/08/2019 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
10/08/2019 THE INSTALLATION SHALL COMPLY WITH ALL APPLICABLE REQUIREMENTS OF SECTION 605.11.1 THROUGH 605.11.4 OF THE 2012 EDITION OF THE INTERNATIONAL FIRE CODE, THE INTERNATIONAL BUILDING CODE AND NFPA 70.

Completed Inspections

Permit Status: Expired
Permit Number: T19CM07358
Permit Description: E - INSTALL ROOFTOP SOLAR SYSTEM
Total Completed Inspections - 5
Date Description Inspector Results Comments
12/04/2019 BULD - Electrical Clearance Passed {Activity date: 12/04/2019; Status: Approved; Inspector: JCLAXTON; Comment: Entered by SFLORES2 - CODE INCR}
12/04/2019 COT - RSEL - Service Upgrade Passed {Activity date: 12/04/2019; Status: Approved; Inspector: JCLAXTON; Comment: Entered by SFLORES2 - } ; {Activity date: 11/27/2019; Status: Not ready for Inspection; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - Roof jack required at riser through roof. Gas bond to be on house side of meter, downstream of all dielectric unions.} ; {Activity date: 11/22/2019; Status: Correction Required; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Grounding Electrode Conductor must run continuously from service to one of the electrodes; can not be a separate one for each ground rod.}
01/30/2020 PDSD Building Division - TEP PM Clearance Passed {Activity date: 01/30/2020; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by SFLORES2 - CODE DGC}
01/30/2020 RSBU - Building Final Passed {Activity date: 01/30/2020; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by SFLORES2 - } ; {Activity date: 01/22/2020; Status: Correction Required; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Provide ladder for inspection.}
01/30/2020 COT - RSEL - Electrical Final Passed {Activity date: 01/30/2020; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by SFLORES2 - ok for clearance DGC} ; {Activity date: 01/22/2020; Status: Correction Required; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Install PV breaker per plan.

} ; {Activity date: 11/22/2019; Status: Not ready for Inspection; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Work incomplete.}

Documents

File Name Document Type  
1_PLANS.PDF CONSTRPLANS VIEW
1_AZ_STRUCTURAL LOAD AND WIND UPLIFT CALC_PRATT REV A.PDF DOCUMENTS VIEW
1_EQUIPMENT SPEC SHEETS. HANWHA 310 AND SMA INVERTER.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
TUCSON PERMIT APPLICATION.PDF DOCUMENTS VIEW