Permit: T19CM06088
Permit Details
Apply Date:
08/23/2019
Applicant:
JESUS RODRIGUEZ
Description:
BEDROOM AND HOBBY ROOM AND BATH ADDITION
Contractors:
- MOUNTAIN VIEW STONE AND TILE INC
Permit Reviews
Permit Number - T19CM06088
Permit Status: Final
Permit Description: BEDROOM AND HOBBY ROOM AND BATH ADDITION
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/23/2019 | RESIDENTIAL - BLDG/ZONING-WALKTHRU | 08/23/2019 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T19CM06088
Permit Status: Final
Permit Description: BEDROOM AND HOBBY ROOM AND BATH ADDITION
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/23/2019 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T19CM06088
Permit Description: BEDROOM AND HOBBY ROOM AND BATH ADDITION
Total Completed Inspections - 14
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/30/2019 | FRAMING | BSTEVENS | Approved | WITHOUT OPENING WALLS THERE IS NO WAY TO VERIFY FRAMING, HOWEVER THE FACT THAT THE STRUCTURE HAS STOOD FOR SEVERAL YEARS WITHOUT ANY SIGN OF CRACKING OR SETTLING INDICATED THAT STRUCTURE IS SUBSTANTIAL. |
| 09/30/2019 | ROOF NAILING | BSTEVENS | Approved | WITHOUT OPENING WALLS THERE IS NO WAY TO VERIFY FRAMING, HOWEVER THE FACT THAT THE STRUCTURE HAS STOOD FOR SEVERAL YEARS WITHOUT ANY SIGN OF CRACKING OR SETTLING INDICATED THAT STRUCTURE IS SUBSTANTIAL. |
| 09/30/2019 | EXT METAL CLIPS/EXT SHEATHING | BSTEVENS | Approved | WITHOUT OPENING WALLS THERE IS NO WAY TO VERIFY FRAMING, HOWEVER THE FACT THAT THE STRUCTURE HAS STOOD FOR SEVERAL YEARS WITHOUT ANY SIGN OF CRACKING OR SETTLING INDICATED THAT STRUCTURE IS SUBSTANTIAL. |
| 11/27/2019 | RESIDENTIAL INTERMEDIATE | MRAMBER | Approved | No access, no message, another failed inspection will result in a reinspection fee. |
| 12/06/2019 | EXCAVATION/LAYOUT REBAR & ZON | DMUNIZ | Approved | |
| 12/06/2019 | PLUMBING - INTERMEDIATE | DMUNIZ | Approved | Master Bath Water closet does not meet Clearances per code requirements, provide a minimum of 15" of Clearance from center of bowl. |
| 12/06/2019 | MECHANICAL - FINAL | DMUNIZ | Approved | Install single wall Flu Vent at Water Heater, flex duct is not acceptable. Provide Exhaust for Master bath/shower. |
| 12/06/2019 | PLUMBING - FINAL | DMUNIZ | Approved | Provide Hammer Arrestors at all Appliances that are required. Install Air admittance valves under sink for main house and guest house. Dishwasher drain line to be installed above flood rim. |
| 12/06/2019 | PLUMBING - ROUGH, SOIL | DMUNIZ | Approved | Plumbing installed prior to inspection, owner disclosed that plumbing was visually inspected via camera. Provide documentation of inspection at Final. |
| 12/06/2019 | ELECTRIC - FINAL | DMUNIZ | Approved | Provide GFCI protection for Exterior outlets, and For Kitchen. GFCI in hall bath not working. Provide combination smoke detector in Hallway. |
| 12/06/2019 | BUILDING - FINAL | DMUNIZ | Approved | see notes. |
| 12/06/2019 | BUILDING PRE-SLAB | DMUNIZ | Approved | work was done previously without permit. Exterior Footers were dug and confirmed to be 12". |
| 12/06/2019 | PLUMBING - INTERMEDIATE | BSTEVENS | Approved | RVI - VIDEO PROVIDED AND ACCEPTED |
| 12/06/2019 | PLUMBING - ROUGH, SOIL | BSTEVENS | Approved | RVI - VIDEO PROVIDED AND ACCEPTED |