Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
Residential Building - One or Two Family
Apply Date:
04/18/2019
Applicant:
Description:
SFR PLAN400318 T18-M0074

Permit Reviews

Permit Number - T19CM02804
Permit Status: Expired
Permit Description: SFR PLAN400318 T18-M0074
Start Date Submittal Complete Date Status  
04/18/2019 RESIDENTIAL - BLDG/ZONING-WALKTHRU 04/19/2019 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T19CM02804
Permit Status: Expired
Permit Description: SFR PLAN400318 T18-M0074
Total Outstanding Activity Conditions - 2
Date Name
04/18/2019 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
04/18/2019 ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I)

Outstanding Inspections

Permit Status: Expired
Permit Number: T19CM02804
Permite Description: SFR PLAN400318 T18-M0074
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
11/07/2022 RSBU - Building Final N/A Canceled Inspection Canceled

Completed Inspections

Permit Status: Expired
Permit Number: T19CM02804
Permit Description: SFR PLAN400318 T18-M0074
Total Completed Inspections - 22
Date Description Inspector Results Comments
06/03/2019 COT - RSPL - Sewer Passed {Activity date: 06/03/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - }
06/03/2019 COT - RSPL - Rough Soil Passed {Activity date: 06/03/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - }
06/07/2019 COT - RSEL - Grounding/Bonding Passed {Activity date: 06/07/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - }
06/07/2019 COT - RSBU - Preslab Passed {Activity date: 06/07/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - Ok for concrete placement}
06/07/2019 COT - RSEL - Electrical Underground Passed {Activity date: 06/07/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - Ok for concrete placement}
06/07/2019 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 06/07/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - Ok for concrete placement}
06/24/2019 COT - RSBU - Roof Nailing Passed {Activity date: 06/24/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - }
06/25/2019 COT - RSBU - Exterior Clips/Sheathing Passed {Activity date: 06/25/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } ; {Activity date: 06/24/2019; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - Install RSP4 & H2.5 hardware where needed.}
07/31/2019 PDSD Building Division - TEP PM Clearance Passed {Activity date: 07/31/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - CODE ECO}
07/31/2019 COT - RSEL - Construction Power Passed {Activity date: 07/31/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - Clear eco
}
08/05/2019 COT - LCPL - Plumbing Intermediate Passed {Activity date: 08/05/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - } ; {Activity date: 08/02/2019; Status: Cancelled; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - Canceled by contractor
}
08/05/2019 COT - RSPL - Yard Water Line Passed {Activity date: 08/05/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - } ; {Activity date: 08/02/2019; Status: Cancelled; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - Canceled by contractor
} ; {Activity date: 06/03/2019; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - Line and tracer ok, no Line Pressure test ok to backfill at own risk.}
08/05/2019 COT - BULD - SWG Clearance Passed {Activity date: 08/05/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - }
08/05/2019 RSEL - Electrical Progress Passed {Activity date: 08/05/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - } ; {Activity date: 08/02/2019; Status: Cancelled; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - Canceled by contractor
}
08/05/2019 RSME - Mechanical Progress Passed {Activity date: 08/05/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - } ; {Activity date: 08/02/2019; Status: Cancelled; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - Canceled by contractor
}
08/05/2019 COT - RSPL - Gas Pressure Test Passed {Activity date: 08/05/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - Clear gas
} ; {Activity date: 08/02/2019; Status: Cancelled; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - Canceled by contractor
}
08/06/2019 COT - LCBU - Framing Passed {Activity date: 08/06/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - All corrections complete
} ; {Activity date: 08/05/2019; Status: Denied; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - 1. Need FHA plates on dwv pipes at 2nd level top plate over bore locations (2 total)
2. Completely nail FHA plate over dryer exhaust vent and range hood vent on 1st floor
3. Missing vent and blocking for fresh air return in garage
4. Foam top plate penetration on north side of garage
5. Shim floor and roof trusses on 1st level where required
6. Move hot water heater B-vent into garage, currently located in bedroom behind garage
7. Finish installing termite line in bedroom behind garage} ; {Activity date: 08/02/2019; Status: Cancelled; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - Canceled by contractor
}
08/12/2019 COT - HCBU - Interior Shear Bracing Passed {Activity date: 08/12/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - }
10/31/2019 COT - RSME - Mechanical Final Passed {Activity date: 10/31/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - }
10/31/2019 COT - RSEL - Outdoor Lighting Passed {Activity date: 10/31/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - }
10/31/2019 COT - RSPL - Plumbing Final Passed {Activity date: 10/31/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - }
10/31/2019 COT - RSEL - Electrical Final Passed {Activity date: 10/31/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - }

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW