08/06/2019 | COT - LCBU - Framing | AKLEINSORGE | Approved | Entered by DMERANZ1 - All corrections complete |
08/05/2019 | COT - LCBU - Framing | AKLEINSORGE | Denied | Entered by DMERANZ1 - 1. Need FHA plates on dwv pipes at 2nd level top plate over bore locations (2 total) 2. Completely nail FHA plate over dryer exhaust vent and range hood vent on 1st floor 3. Missing vent and blocking for fresh air return in garage 4. Foam top plate penetration on north side of garage 5. Shim floor and roof trusses on 1st level where required 6. Move hot water heater B-vent into garage, currently located in bedroom behind garage 7. Finish installing termite line in bedroom behind garage |
08/02/2019 | COT - LCBU - Framing | AKLEINSORGE | Cancelled | Entered by DMERANZ1 - Canceled by contractor |