Permit: T19CM02804

Parcel: 141364930

Inspection Status: Passed

Inspection History: COT - LCBU - Framing

Permit Number - T19CM02804

Inspection Description - COT - LCBU - Framing

Inspection Status - Passed

Date Description Inspector Results Comments
08/06/2019 COT - LCBU - Framing AKLEINSORGE Approved Entered by DMERANZ1 - All corrections complete
08/05/2019 COT - LCBU - Framing AKLEINSORGE Denied Entered by DMERANZ1 - 1. Need FHA plates on dwv pipes at 2nd level top plate over bore locations (2 total) 2. Completely nail FHA plate over dryer exhaust vent and range hood vent on 1st floor 3. Missing vent and blocking for fresh air return in garage 4. Foam top plate penetration on north side of garage 5. Shim floor and roof trusses on 1st level where required 6. Move hot water heater B-vent into garage, currently located in bedroom behind garage 7. Finish installing termite line in bedroom behind garage
08/02/2019 COT - LCBU - Framing AKLEINSORGE Cancelled Entered by DMERANZ1 - Canceled by contractor