Permit: T19CM02793
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
5233 S HAMPTON ROADS DR
Address NEW:
5233 S HAMPTON ROADS DR
Apply Date:
04/18/2019
Applicant:
PIMA VENTURES LLC
Description:
ADD BATH,UPGRADE ELECTRICAL PANEL, UPGRADE AC
Contractors:
- PIMA VENTURES LLC
Permit Reviews
Permit Number - T19CM02793
Permit Status: Expired
Permit Description: ADD BATH,UPGRADE ELECTRICAL PANEL, UPGRADE AC
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/18/2019 | RESIDENTIAL - BLDG/ZONING-WALKTHRU | 04/18/2019 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T19CM02793
Permit Status: Expired
Permit Description: ADD BATH,UPGRADE ELECTRICAL PANEL, UPGRADE AC
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/18/2019 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T19CM02793
Permite Description: ADD BATH,UPGRADE ELECTRICAL PANEL, UPGRADE AC
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/27/2019 | BUILDING - FINAL | N/A | Not ready for Inspection | mechanical system is not per drawing, plans call for a 3.5 ton split unit on roof with heat pump. That is not what is installed, either revise drawings or build per drawing. Also a new system requires a service receptacle on roof. If current system is approved need to see specifications on the correct amount of return air as it does not appear to be sufficient, also unit is over fused and we’ll need to see where condensate terminates. |
Completed Inspections
Permit Status: Expired
Permit Number: T19CM02793
Permit Description: ADD BATH,UPGRADE ELECTRICAL PANEL, UPGRADE AC
Total Completed Inspections - 10
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/10/2019 | PLUMBING - ROUGH, SOIL | AKLEINSORGE | Approved | Ok to backfill |
| 05/16/2019 | PLUMBING - INTERMEDIATE | RCAMACHO | Approved | |
| 05/17/2019 | ELECTRIC - INTERMEDIATE | RCAMACHO | Approved | |
| 05/17/2019 | FRAMING | RCAMACHO | Approved | |
| 05/22/2019 | SHEET ROCK NAILING | RCAMACHO | Approved | |
| 06/12/2019 | TEP CLEARANCE - PM | MHASSAN | Approved | CODE INCR |
| 06/12/2019 | ELECTRIC - SERVICE UPGRADE | MHASSAN | Approved | OK to clear electric INCR |
| 06/27/2019 | ELECTRIC - FINAL | MHASSAN | Approved | |
| 06/27/2019 | PLUMBING - FINAL | MHASSAN | Approved | |
| 06/27/2019 | ELECTRIC - RECONNECT | MHASSAN | Approved |