Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T19CM02712
Permit Details
Apply Date:
04/16/2019
Applicant:
Description:
SFR EAST16402 T18-M0037
Permit Reviews
Permit Number - T19CM02712
Permit Status: Issued
Permit Description: SFR EAST16402 T18-M0037
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/16/2019 | RESIDENTIAL - BLDG/ZONING-WALKTHRU | 04/16/2019 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T19CM02712
Permit Status: Issued
Permit Description: SFR EAST16402 T18-M0037
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
04/16/2019 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Conditions
Permit Number - T19CM02712
Permit Status: Issued
Permit Description: SFR EAST16402 T18-M0037
Date | Description | Comments |
---|---|---|
04/16/2019 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
Outstanding Inspections
Permit Status: Issued
Permit Number: T19CM02712
Permite Description: SFR EAST16402 T18-M0037
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/27/2022 | RSBU - Building Final | N/A | Not Ready |
Completed Inspections
Permit Status: Issued
Permit Number: T19CM02712
Permit Description: SFR EAST16402 T18-M0037
Total Completed Inspections - 20
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/14/2019 | COT - RSPL - Rough Soil | Passed | {Activity date: 06/14/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } | |
06/19/2019 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 06/19/2019; Status: Approved; Inspector: GWEST; Comment: Entered by DMERANZ1 - } | |
06/19/2019 | COT - RSEL - Electrical Underground | Passed | {Activity date: 06/19/2019; Status: Approved; Inspector: GWEST; Comment: Entered by DMERANZ1 - } | |
06/26/2019 | COT - RSBU - Preslab | Passed | {Activity date: 06/26/2019; Status: Approved; Inspector: GWEST; Comment: Entered by DMERANZ1 - Open line items, no more FTC or slab after this} ; {Activity date: 06/19/2019; Status: Approved; Inspector: GWEST; Comment: Entered by DMERANZ1 - } | |
06/26/2019 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 06/26/2019; Status: Approved; Inspector: GWEST; Comment: Entered by DMERANZ1 - Open line items, no more FTC or slab after this} ; {Activity date: 06/19/2019; Status: Approved; Inspector: GWEST; Comment: Entered by DMERANZ1 - } | |
07/11/2019 | COT - RSBU - Roof Nailing | Passed | {Activity date: 07/11/2019; Status: Approved; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - } ; {Activity date: 06/28/2019; Status: Not ready for Inspection; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } | |
07/22/2019 | COT - RSBU - Exterior Clips/Sheathing | Passed | {Activity date: 07/22/2019; Status: Approved; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - } ; {Activity date: 07/11/2019; Status: Partial Approval; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - South east corner of garage not complete.} ; {Activity date: 06/28/2019; Status: Not ready for Inspection; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } | |
08/07/2019 | COT - RSPL - Yard Water Line | Passed | {Activity date: 08/07/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - Ok to backfill. } ; {Activity date: 06/14/2019; Status: Not ready for Inspection; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } |
|
08/07/2019 | COT - RSPL - Sewer | Passed | {Activity date: 08/07/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - Ok to backfill. } |
|
08/19/2019 | RSEL - Electrical Progress | Passed | {Activity date: 08/19/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } | |
08/19/2019 | RSME - Mechanical Progress | Passed | {Activity date: 08/19/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } ; {Activity date: 07/26/2019; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by VFLORES1 - Block all Duct Vents, call in inspection when all intermediates are complete.} | |
09/03/2019 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 09/03/2019; Status: Approved; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - } ; {Activity date: 08/22/2019; Status: Not ready for Inspection; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - 1-Water heater is installed in room with opening less than 24" wide per M1305.1.1. 2-Need a minimum of 18" of copper from water heater before transitioning to pex. 3-Remove insulation to allow completion of inspection. 4-several studs have been over-notched or over-drilled per R602.6.} ; {Activity date: 08/19/2019; Status: Not ready for Inspection; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Work incomplete at this time.} |
|
10/09/2019 | PDSD Building Division - TEP PMÂ Clearance | Passed | {Activity date: 10/09/2019; Status: Approved; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - CODE ECO} | |
10/09/2019 | COT - RSEL - Construction Power | Passed | {Activity date: 10/09/2019; Status: Approved; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - ECO ok to clear.} | |
02/10/2020 | COT - RSME - Mechanical Final | Passed | {Activity date: 02/10/2020; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
02/10/2020 | COT - LCBU - Framing | Passed | {Activity date: 02/10/2020; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } ; {Activity date: 06/28/2019; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by DMERANZ1 - Porch footings ok to pour} ; {Activity date: 06/26/2019; Status: Not Applicable; Inspector: GWEST; Comment: Entered by DMERANZ1 - } | |
02/10/2020 | COT - RSEL - Outdoor Lighting | Passed | {Activity date: 02/10/2020; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
02/10/2020 | COT - RSPL - Plumbing Final | Passed | {Activity date: 02/10/2020; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
02/10/2020 | RSPL - Plumbing Progress | Passed | {Activity date: 02/10/2020; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
02/10/2020 | COT - RSEL - Electrical Final | Passed | {Activity date: 02/10/2020; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } |