Permit Details
Status:
Expired
Type:
SINGLE FAMILY ALTERATION
Address:
1221 E GANLEY RD #07
Address NEW:
1221 E GANLEY RD #07
Apply Date:
03/15/2019
Applicant:
INAI ANZUETO
Description:
DEMO PORCH AND INSTALL 4 MINI SPLIT UNITS
Permit Reviews
Permit Number - T19CM01875
Permit Status: Expired
Permit Description: DEMO PORCH AND INSTALL 4 MINI SPLIT UNITS
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/15/2019 | RESIDENTIAL - BLDG/ZONING-WALKTHRU | 03/15/2019 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T19CM01875
Permit Status: Expired
Permit Description: DEMO PORCH AND INSTALL 4 MINI SPLIT UNITS
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/15/2019 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T19CM01875
Permite Description: DEMO PORCH AND INSTALL 4 MINI SPLIT UNITS
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/29/2019 | RESIDENTIAL INTERMEDIATE | N/A | Not ready for Inspection | per previous correction still need 4 new 20 amp circuits and they need to be labeled in panel. Blocking on the roof has rotted away and units are not secure on the roof. Please provide either pressure-treated or redwood blocking. Exposed wiring on roof needs to be addressed. Secure line sets. Terminate condensate piping properly. Only inspected outside. It was recommended to homeowner to hire a licensed mechanical contractor for these repairs. |
| 05/29/2019 | BUILDING - FINAL | N/A | Not ready for Inspection | per previous correction still need 4 new 20 amp circuits and they need to be labeled in panel. Blocking on the roof has rotted away and units are not secure on the roof. Please provide either pressure-treated or redwood blocking. Exposed wiring on roof needs to be addressed. Secure line sets. Terminate condensate piping properly. Only inspected outside. It was recommended to homeowner to hire a licensed mechanical contractor for these repairs. |
| 05/29/2019 | ELECTRIC - FINAL | N/A | Not ready for Inspection | per previous correction still need 4 new 20 amp circuits and they need to be labeled in panel. Blocking on the roof has rotted away and units are not secure on the roof. Please provide either pressure-treated or redwood blocking. Exposed wiring on roof needs to be addressed. Secure line sets. Terminate condensate piping properly. Only inspected outside. It was recommended to homeowner to hire a licensed mechanical contractor for these repairs. |