Permit Details

Status:
Expired
Type:
SINGLE FAMILY ALTERATION
Address NEW:
1221 E GANLEY RD #07
Apply Date:
03/15/2019
Applicant:
INAI ANZUETO
Description:
DEMO PORCH AND INSTALL 4 MINI SPLIT UNITS

Permit Reviews

Permit Number - T19CM01875
Permit Status: Expired
Permit Description: DEMO PORCH AND INSTALL 4 MINI SPLIT UNITS
Start Date Submittal Complete Date Status  
03/15/2019 RESIDENTIAL - BLDG/ZONING-WALKTHRU 03/15/2019 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T19CM01875
Permit Status: Expired
Permit Description: DEMO PORCH AND INSTALL 4 MINI SPLIT UNITS
Total Outstanding Activity Conditions - 1
Date Name
03/15/2019 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T19CM01875
Permite Description: DEMO PORCH AND INSTALL 4 MINI SPLIT UNITS
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
05/29/2019 RESIDENTIAL INTERMEDIATE N/A Not ready for Inspection per previous correction still need 4 new 20 amp circuits and they need to be labeled in panel. Blocking on the roof has rotted away and units are not secure on the roof. Please provide either pressure-treated or redwood blocking. Exposed wiring on roof needs to be addressed. Secure line sets. Terminate condensate piping properly. Only inspected outside. It was recommended to homeowner to hire a licensed mechanical contractor for these repairs.
05/29/2019 BUILDING - FINAL N/A Not ready for Inspection per previous correction still need 4 new 20 amp circuits and they need to be labeled in panel. Blocking on the roof has rotted away and units are not secure on the roof. Please provide either pressure-treated or redwood blocking. Exposed wiring on roof needs to be addressed. Secure line sets. Terminate condensate piping properly. Only inspected outside. It was recommended to homeowner to hire a licensed mechanical contractor for these repairs.
05/29/2019 ELECTRIC - FINAL N/A Not ready for Inspection per previous correction still need 4 new 20 amp circuits and they need to be labeled in panel. Blocking on the roof has rotted away and units are not secure on the roof. Please provide either pressure-treated or redwood blocking. Exposed wiring on roof needs to be addressed. Secure line sets. Terminate condensate piping properly. Only inspected outside. It was recommended to homeowner to hire a licensed mechanical contractor for these repairs.

Documents

File Name Document Type  
001_SHEET 1 OF 2.TIF CONSTRPLANS VIEW
002_SHEET 2 OF 2.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW