Permit: T19CM00883
Permit Details
Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
3533 N COUNTRY CLUB RD
Address NEW:
3533 N COUNTRY CLUB RD
Apply Date:
02/05/2019
Applicant:
RAM PLUMBING INC
Description:
REPLACE GAS LINE
Contractors:
- RAM PLUMBING ***APA***
- RAM PLUMBING INC
Permit Reviews
Permit Number - T19CM00883
Permit Status: Final
Permit Description: REPLACE GAS LINE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/05/2019 | WALK THRU - RES | 02/05/2019 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T19CM00883
Permit Status: Final
Permit Description: REPLACE GAS LINE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 02/05/2019 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T19CM00883
Permit Description: REPLACE GAS LINE
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/06/2019 | PLUMBING - FINAL | TVALENCIA | Approved | All corrections have been made. Clear gas meter Verbal clearance called in at 2:53pm |
| 02/06/2019 | PLUMBING - FINAL | TVALENCIA | Approved | 1- Shall provide (3) sheet metal screws per joint on the water heater flu vent and draft collar and remove the mechanical tape around the dbl wall flu vent. 2- Shall provide a gas bond on the system. 3- Shall extend and terminate the wall heaterflu vent (3) feet above the cooler. 4- Shall extend and terminate the water heater T & P drain to daylight. 5- Shall secure the gas line drop to the wall furnace. |
| 02/06/2019 | PLUMBING - GAS PRESSURE TEST | TVALENCIA | Approved | |
| 02/07/2019 | GAS CLEARANCE | TVALENCIA | Approved |