Permit: T19CM00847
Permit Details
Status:
Expired
Type:
Residential Building - One or Two Family
Address:
6051 E 29TH ST
Address NEW:
6051 E 29TH ST
Apply Date:
02/04/2019
Applicant:
Description:
ELECTRICAL RECONNECT
Permit Reviews
Permit Number - T19CM00847
Permit Status: Expired
Permit Description: ELECTRICAL RECONNECT
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/06/2019 | REVISION - - 1ST | 08/06/2019 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T19CM00847
Permit Status: Expired
Permit Description: ELECTRICAL RECONNECT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 02/04/2019 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T19CM00847
Permite Description: ELECTRICAL RECONNECT
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/07/2022 | COT - RSEL - Electrical Final | N/A | Canceled | Inspection Canceled |
Completed Inspections
Permit Status: Expired
Permit Number: T19CM00847
Permit Description: ELECTRICAL RECONNECT
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/17/2019 | COT - RSEL - Service Relocation | Passed | {Activity date: 09/17/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Clearance TEP INCR.} | |
| 09/17/2019 | PDSD Building Division - TEP PMÂ Clearance | Passed | {Activity date: 09/17/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - CODE INCR} | |
| 09/17/2019 | COT - RSEL - Service Upgrade | Passed | {Activity date: 09/17/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } | |
| 09/17/2019 | COT - RSEL - Electrical Reconnect | Passed | {Activity date: 09/17/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } ; {Activity date: 04/10/2019; Status: Not ready for Inspection; Inspector: DQUINN; Comment: Entered by CBELL1 - New electric panels installed without permit. A sub panel in a bedroom closet can not be replaced and remain in a closet. The new main panel appears to close to the gas meter. Contact southwest gas for approval. Obtain permit for electric and new interior plumbing lines.} ; {Activity date: 02/07/2019; Status: Denied; Inspector: DQUINN; Comment: Entered by CBELL1 - Missing wiring and panel covers on exterior main panels. Front security door would not open when locks were unlocked. House not entered. Have licensed electrician correct all deficiencies at the main panels and any electrical hazards found inside the house before re-calling.} |