Permit: T19CM00486
Permit Details
Apply Date:
01/24/2019
Applicant:
MEYER WILLIAM (CHUCK)
Description:
RESTURANT
Architects:
- MEYER WILLIAM (CHUCK)
Contractors:
- PATE CONTRACTORS LLC
Permit Reviews
Permit Number - T19CM00486
Permit Status: C of o
Permit Description: RESTURANT
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/24/2019 | COMMERCIAL - TI | 01/24/2019 | COMPLETED |
01/24/2019 | COMMERCIAL - TI | 04/04/2019 | COMPLETED |
04/04/2019 | RESUBMITTAL | 04/29/2019 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T19CM00486
Permit Status: C of o
Permit Description: RESTURANT
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
01/24/2019 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T19CM00486
Permit Description: RESTURANT
Total Completed Inspections - 21
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/14/2019 | ELECTRIC - INTERMEDIATE | ESTEVENS | Approved | |
06/14/2019 | MECHANICAL - INTERMEDIATE | ESTEVENS | Approved | |
06/20/2019 | FRAMING | RCAMACHO | Approved | |
06/21/2019 | PLUMBING - INTERMEDIATE | ESTEVENS | Approved | |
06/26/2019 | PLUMBING - GAS PRESSURE TEST | RCAMACHO | Approved | |
06/26/2019 | BUILDING ABOVE CEILING | RCAMACHO | Approved | |
06/28/2019 | BUILDING - PROGRESS | ESTEVENS | Approved | |
06/28/2019 | TEP CLEARANCE - PM | ESTEVENS | Approved | CODE ECO |
06/28/2019 | ELECTRIC - SERVICE UPGRADE | ESTEVENS | Approved | The TEP clearance code is ECO. |
07/23/2019 | ELECTRIC - ABOVE CEILING | ESTEVENS | Approved | |
07/24/2019 | FIRE - ALARM FINAL | MRoss | Approved | |
07/24/2019 | FIRE SPKLR - FINAL | MRoss | Approved | |
07/26/2019 | ELECTRIC - FINAL | ESTEVENS | Approved | |
07/26/2019 | FIRE - KITCHEN EXH HOOD FINAL | jvincent | Approved | |
07/26/2019 | FIRE INTERMEDIATE | jvincent | Approved | |
07/29/2019 | MECHANICAL - FINAL | RSHERRY | Approved | REVIEW OF AIR BALANCE REPORT COMPLETED |
07/29/2019 | PLUMBING - FINAL | RSHERRY | Approved | REVIEW OF WATER DISINFECTION REPORT COMPLETED |
07/30/2019 | FIRE - FINAL | Mross | Approved | |
07/31/2019 | BUILDING - FINAL | TVALENCIA | Approved | 1-All corrections have been made, recommend for C of O. |
07/31/2019 | BUILDING - FINAL | TVALENCIA | Approved | 1- Shall provide a 1022 in line backflow preventer devise at the soap dispenser at Mop Sink. 2- Shall locate the the Accessible signage for restrooms on the latch side of doors. 3- Shall provide 10 seconds of flow on accessible lavatories 4- Shall provide water hammer arrestors for the pressure assist water closets. 5- Shall provide a label on the ceiling tile the location of the Anzul Valve. |
08/01/2019 | CERTIFICATE OF OCCUPANCY | TVALENCIA | Approved |