Permit: T19CM00486

Parcel: 115043270

Inspection Status: Denied

Inspection History: BUILDING - FINAL

Permit Number - T19CM00486

Inspection Description - BUILDING - FINAL

Inspection Status - Denied

Date Description Inspector Results Comments
07/31/2019 BUILDING - FINAL Denied 1- Shall provide a 1022 in line backflow preventer devise at the soap dispenser at Mop Sink.
2- Shall locate the the Accessible signage for restrooms on the latch side of doors.
3- Shall provide 10 seconds of flow on accessible lavatories
4- Shall provide water hammer arrestors for the pressure assist water closets.
5- Shall provide a label on the ceiling tile the location of the Anzul Valve.
07/31/2019 BUILDING - FINAL Approved 1-All corrections have been made, recommend for C of O.
07/26/2019 BUILDING - FINAL Partial Approval Pending other inspections.