Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
1825 N NORTON AV
Address NEW:
1825 N NORTON AV
Apply Date:
01/17/2019
Applicant:
PIONEER PLUMBING *APA*
Description:
GAS REPIPE
Contractors:
  • PIONEER PLUMBING *APA*

Permit Reviews

Permit Number - T19CM00349
Permit Status: Expired
Permit Description: GAS REPIPE
Start Date Submittal Complete Date Status  
01/17/2019 WALK THRU - RES 01/18/2019 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T19CM00349
Permit Status: Expired
Permit Description: GAS REPIPE
Total Outstanding Activity Conditions - 1
Date Name
01/17/2019 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T19CM00349
Permite Description: GAS REPIPE
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
02/08/2019 PLUMBING - FINAL N/A Correction Required Water Heater. P&T drain line to be 3/4 inch interior diameter and no PVC.
Drip req on gas supply line .
Thimble at ceiling req for B vent clearance per manufacturer.
3 Tec screws req at vent connector to B vent and B vent to water heater draft hood.
Combustion air required at door. 100 sq in within 12 in of the ceiling and within 12 in of the floor.

Completed Inspections

Permit Status: Expired
Permit Number: T19CM00349
Permit Description: GAS REPIPE
Total Completed Inspections - 2
Date Description Inspector Results Comments
02/08/2019 PLUMBING - GAS PRESSURE TEST GWEST Approved
02/11/2019 GAS CLEARANCE GWEST Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW