| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/17/2019 | WALK THRU - RES | 01/18/2019 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T19CM00349
Permit Status: Expired
Permit Description: GAS REPIPE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/17/2019 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T19CM00349
Permite Description: GAS REPIPE
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/08/2019 | PLUMBING - FINAL | N/A | Correction Required | Water Heater. P&T drain line to be 3/4 inch interior diameter and no PVC. Drip req on gas supply line . Thimble at ceiling req for B vent clearance per manufacturer. 3 Tec screws req at vent connector to B vent and B vent to water heater draft hood. Combustion air required at door. 100 sq in within 12 in of the ceiling and within 12 in of the floor. |
Completed Inspections
Permit Status: Expired
Permit Number: T19CM00349
Permit Description: GAS REPIPE
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/08/2019 | PLUMBING - GAS PRESSURE TEST | GWEST | Approved | |